MAMMOTH CAVE NATIONAL PARK, KY —
OSHA Inspection: INTEX SYSTEMS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of INTEX SYSTEMS INC. in 1 MAMMOTH CAVE DRIVE VISITORS' CENTER, MAMMOTH CAVE NATIONAL PARK, KY 42259 (NAICS 238320). OSHA activity number 346725906.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INTEX SYSTEMS INC.
- Site address
- 1 MAMMOTH CAVE DRIVE VISITORS' CENTER
- City
- MAMMOTH CAVE NATIONAL PARK
- State
- KY
- ZIP
- 42259
- Mailing
- 1001 WEST KENTUCKY STREET, LOUISVILLE, KY 40210
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238320
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.403 B01 I
- Issued
- Jul 26, 2023
- Penalty
- Initial $1,808 · Current $1,085 Reduced
General-duty citation text
29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose: a) On or about May 23, 2023 in the lodge employees were exposed to fire hazards in that flexible cord sets were utilized to provide electricity to permanent panelboards circuits and the employer did not ensure electrical equipment was suitable as evidenced by listing, labeling or certification for the use.
Recent events (2)
- — I (S) $1084.8
- — Z (S) $1808
1926.502 I03
- Issued
- Jul 26, 2023
- Penalty
- Initial $2,712 · Current $1,627 Reduced
General-duty citation text
29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees: a) On or about May 23, 2023 in the foyer area employees were exposed to fall hazards and the employer did not ensure all covers were secured when installed so as to prevent accidental displacement by equipment or employees. b) On or about May 23, 2023 in the foyer adjacent area employees were exposed to fall hazards and the employer did not ensure all covers were secured when installed so as to prevent accidental displacement by equipment or employees.
Recent events (2)
- — I (S) $1627.2
- — Z (S) $2712
1926.502 I04
- Issued
- Jul 26, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard: a) On or about May 23, 2023 in the foyer area employees were exposed to fall hazards and the employer did not ensure all covers were color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard. b) On or about May 23, 2023 in the foyer adjacent area employees were exposed to fall hazards and the employer did not ensure all covers were color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Intex Systems INC.
View Intex Systems INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238320)
More inspections in KY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346725906.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.