Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACTIVE VENTILATION PRODUCTS INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ACTIVE VENTILATION PRODUCTS INC in 311 1ST ST, NEWBURGH, NY 12550 (NAICS 332322). OSHA activity number 346726235.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Active Ventilation Products INC — free Get an email when a new federal OSHA severe-injury report for Active Ventilation Products INC is published. One employer, no account, unsubscribe in one click.
Site address
311 1ST ST
City
NEWBURGH
State
NY
ZIP
12550
Mailing
311 1ST ST, NEWBURGH, NY 12550
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
40
Ownership type
A

4 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 1, 2023
Abate by
Nov 14, 2023
Penalty
Initial $7,813 · Current $7,813
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  a) Stamping Room - On or about May 5, 2023 and at times prior thereto, the employer did not provide an energy control program that included procedures, training, and inspections for employees clearing jams on the forming die.
Recent events (2)
  • — I (S) $7813
  • — Z (S) $7813

1910.147 C04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 1, 2023
Abate by
Nov 13, 2023
Penalty
Initial $7,813 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) Stamping Room - On or about May 5, 2023 and at times prior thereto, an employee was required to clear a jam on a Rousselle Stamping Press. The employer did not provide an energy control program that included procedures for employees clearing jams on the Rousselle Stamping Press.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7813

1910.147 C07 I

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 1, 2023
Abate by
Nov 13, 2023
Penalty
Initial $7,813 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:  a) Stamping Room - On or about May 5, 2023 and at times prior thereto, the employer did not provide training as part of an energy control program for employees clearing jams on the forming die.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7813

1904.39 A02

Deleted Other-than-serious 1 instance 1 exposed
Issued
Nov 1, 2023
Penalty
Initial $7,813 · Current $0 Reduced
29 CFR 1904.39(a)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye:  a) Facility - On or about May 5, 2023 and at times prior thereto, the employer did not report an incident that resulted in the hospitalization and amputation of a fingertip within 24 hours.  The incident was reported 10 days following on May 15, 2023.
Recent events (2)
  • — I (O) $0
  • — Z (O) $7813

View Active Ventilation Products INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346726235.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.