Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MACON SEPTIC SYSTEMS, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MACON SEPTIC SYSTEMS, INC in 17932 U.S. 45, MACON, MS 39341 (NAICS 327320). OSHA activity number 346726748.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Macon Septic Systems, INC — free Get an email when a new federal OSHA severe-injury report for Macon Septic Systems, INC is published. One employer, no account, unsubscribe in one click.
Site address
17932 U.S. 45
City
MACON
State
MS
ZIP
39341
Mailing
17932 U.S. 45, MACON, MS 39341
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
13
Ownership type
A

7 citations on file for this inspection.

1910.147 C01

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 14, 2023
Abate by
Sep 13, 2023
Penalty
Initial $2,678 · Current $2,678
29 CFR  1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  (a) Macon Septic Systems Inc.  - On or about May 24, 2023, the employer did not  have a  energy control program for employees that perform servicing and maintenance on machinery such as but not limited to the Lehman Shear exposing employees to caught-in and struck-by hazards.
Recent events (1)
  • — Z (S) $2678

1910.212 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 14, 2023
Abate by
Sep 13, 2023
Penalty
Initial $5,358 · Current $5,358
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Lehman Shear - On or about May 24, 2023, the employer did not install guarding for the Lehman Shear, exposing operators to caught-in hazards.
Recent events (1)
  • — Z (S) $5358

1910.305 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 14, 2023
Abate by
Sep 13, 2023
Penalty
Initial $2,678 · Current $2,678
29 CFR  1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures.  (a) Lehman Shear Outside Open Location - On or about May 24, 2023, the employer did not install weatherproof electrical enclosures  exposing employees to electrical shock hazard.
Recent events (1)
  • — Z (S) $2678

1904.39 A02

Other-than-serious 1 instance 13 exposed
Issued
Aug 14, 2023
Penalty
Initial $4,465 · Current $4,465
29 CFR  1904.39(a)(2):The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye.  (a) Macon Septic Systems Inc. - On or about May 24, 2023 the employer did not report the amputations of an employee that suffered a work related injury  on May 11, 2023 until May 18, 2023.
Recent events (1)
  • — Z (O) $4465

1910.305 G01 IV A

Other-than-serious 1 instance 2 exposed
Issued
Aug 14, 2023
Abate by
Sep 13, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.  (a) Lehman Shear - On or about May 24, 2023 flexible wiring was used to supply electrical energy to permanent location exposing employees to an electrical shock hazard.
Recent events (1)
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 13 exposed
Issued
Aug 14, 2023
Abate by
Sep 13, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met.  (a)  Macon Septic Systems Inc.  - On or about May 24, 2023, the employer had not developed and implemented a written hazard communication program governing the usage of hazardous chemicals, such as but not limited to, Portland Cement, exposing employees to chemical hazards.
Recent events (1)
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 13 exposed
Issued
Aug 14, 2023
Abate by
Sep 13, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:   (a)  Macon Septic Systems Inc.  - On or about May 24, 2023, the employer did not train employees that use chemicals such as, but not limited to, Portland Cement, exposing the employees to chemical hazards.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346726748.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.