Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SMALL'S SAND & GRAVEL INC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of SMALL'S SAND & GRAVEL INC in 10229 KILLDUFF ROAD, GAMBIER, OH 43022 (NAICS 212321). OSHA activity number 346731490.

Watch Small'S Sand & Gravel INC — free Get an email when a new federal OSHA severe-injury report for Small'S Sand & Gravel INC is published. One employer, no account, unsubscribe in one click.
Site address
10229 KILLDUFF ROAD
City
GAMBIER
State
OH
ZIP
43022
Mailing
ATTN: ROMAN ARCE, ESQ., FOUR SEAGATE BLDG, 8TH FLOOR, 433 N. SUMMIT ST., TOLEDO, OH 43604
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
212321
Employees
71
Ownership type
A

2 citations on file for this inspection.

1910.180 D05 II

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $10938.00 · Current $6235.00 Reduced
29 CFR  1910.180(d)(5)(ii):  A crane which has been idle for a period of six months shall be given a complete inspection conforming with requirements of paragraphs (d) (3) and (4) of this section and paragraph (g)(2)(ii) of this section before placing in service.  a. On or about May 25, 2023, the employer did not ensure that the Grove TM225, Serial 661346, 25-Ton truck mounted crane that was idle for the past six months was inspected in accordance with the (d)(3) Frequent Inspection, (d)(4) Periodic Inspection and (g)(2)(ii) Wire Rope Inspection requirements in order to identify deficiencies which could affect the safe operation of the crane prior to hoisting concrete wall barrier blocks to calibrate the AC tank scale , thereby exposing employees to crushed-by hazards.
Recent events (2)
  • — I (S) $6234.66
  • — Z (S) $10938

1910.180 H03 IX

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $15625.00 · Current $8765.00 Reduced
29 CFR  1910.180(h)(3)(ix):  Outriggers shall be used when the load to be handled at that particular radius exceeds the rated load without outriggers as given by the manufacturer for that crane. Where floats are used they shall be securely attached to the outriggers. Wood blocks used to support outriggers shall:  a. On or about May 25, 2023, the employer did not ensure that outriggers for the Grove TM225, Serial 661346, 25-Ton truck mounted crane were extended and positioned prior to operating the crane to hoist an approximately 3,400 pound concrete wall barrier block to calibrate the AC tank scale. The crane was overturned as a result of being operated outside the rated load limits established by the equipment manufacturer, thereby exposing employees to crushed-by hazards.
Recent events (2)
  • — I (S) $8765.34
  • — Z (S) $15625

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346731490.