MECHANICSBURG, PA —
OSHA Inspection: SUNNYMAC SOLAR
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SUNNYMAC SOLAR in 21 RYCROFT ROAD, MECHANICSBURG, PA 17050 (NAICS 238210). OSHA activity number 346733355.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUNNYMAC SOLAR
- Site address
- 21 RYCROFT ROAD
- City
- MECHANICSBURG
- State
- PA
- ZIP
- 17050
- Mailing
- 413 8TH AVENUE, WILMINGTON, DE 19805
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Sep 27, 2023
- Penalty
- Initial $4,688 · Current $4,688
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 21 Rycroft Road, Mechanicsburg PA, Roof, - Employees performed solar installation activities on a two-story residential roof, approximately 21 feet above grade with an 10/12 roof pitch, without utilizing any means of fall protection, on or about May 25, 2023. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
- — Z (S) $4688
1926.1053 B22
- Issued
- Sep 27, 2023
- Abate by
- Oct 24, 2023
- Penalty
- Initial $3,349 · Current $3,349
General-duty citation text
29 CFR 1926.1053(b)(22):Employees using ladders were carrying objects or loads that could cause the employee to lose balance and fall: a) 21 Rycroft Road, Mechanicsburg PA, Roof, - Employees performed solar installation activities on a two-story residential roof, employees carried solar panels that weigh 40 pounds up an extension ladder, on or about May 25, 2023. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
- — Z (S) $3349
More inspections at Sunnymac Solar
View Sunnymac Solar's full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346733355.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.