Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DAYS INN CHAMBERS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DAYS INN CHAMBERS in I-40/HWY.191, CHAMBERS, AZ 86502 (NAICS 721110). OSHA activity number 346741200.

Watch Days INN Chambers — free Get an email when a new federal OSHA severe-injury report for Days INN Chambers is published. One employer, no account, unsubscribe in one click.
Establishment
DAYS INN CHAMBERS
Site address
I-40/HWY.191
City
CHAMBERS
State
AZ
ZIP
86502
Mailing
P.O. BOX 39, CHAMBERS, AZ 86502
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721110
Employees
20
Ownership type
A

7 citations on file for this inspection.

1910.1200 E01

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4687.00 · Current $2000.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:   Hazard Communication Program - The employer did not develop a written Hazard Communication Program for employees in the housekeeping and laundry departments who when use products such as but not limited to, Ecolab laundry and cleaning products and bleach, on a daily basis.  Employees are exposed to skin and lung irritation hazards.  The written program shall include the following:   1. A list of all hazardous chemicals used at the work site;  1. Current Safety Data Sheets (SDS's);               2. A description of the pictogram system:             3. A description of the labeling system that will be used in the workplace;  4. A description of training and information provided to affected employees.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4687

1910.1200 G08

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical:  Hazard Communication Program -  The employer did not maintain safety data sheets (SDS's) for each hazardous chemical product used in the workplace, such as but not limited to, Ecolab laundry and cleaning products, and bleach.  Employees are exposed to skin and eye irritation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 1 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:   Hazard Communication Program - The employer did not provide the required information and training to employees using hazardous chemical products such as but not limited to, Ecolab laundry and cleaning products, and bleach.  Employees are exposed to skin and eye irritation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4687.00 · Current $2000.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   Laundry Bldg. - A relocatable power tap was used as a substitute for fixed wiring to energize the Ecolab pump system connected to the washer machines.  Employees are exposed to electrical and/or fire hazards.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4687

1910.305 B02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4687.00 · Current $2000.00 Reduced
29 CFR 1910.305(b)(2)(i):  Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy.  Laundry Bldg. - The faceplate on a wall outlet (120V) was missing exposing live electrical parts.  Employees are exposed to shock hazards.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4687

1910.303 G01

Other-than-serious 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment:  Laundry Bldg. -  Two electrical panel boards (120-240V)  used to energize laundry equipment and lighting were blocked by various types of materials.  A 3- foot clearance was not maintained as required.   Employees are exposed to fire hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.22 A01

Other-than-serious 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition.   Backside of hotel/laundry bldg. - The general area behind the hotel was excessively strewn with garbage and renovation debris.  Employees are exposed to slip, trip and fall hazards and general unsanitary conditions.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346741200.