LEOPOLIS, WI —
OSHA Inspection: U.S. POSTAL SERVICE
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of U.S. POSTAL SERVICE in N4952 4TH ST, LEOPOLIS, WI 54948 (NAICS 491110). OSHA activity number 346743321.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. POSTAL SERVICE
- Site address
- N4952 4TH ST
- City
- LEOPOLIS
- State
- WI
- ZIP
- 54948
- Mailing
- N4952 4TH ST, LEOPOLIS, WI 54948
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 491110
- Employees
- 1
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.303 B02
- Issued
- Sep 21, 2023
- Penalty
- Initial $8,929 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. On or about June 2, 2023, at the establishment located at N4952 4th Street Leopolis, Wisconsin; two relocatable power taps (RTP) were daisy chained to power 12 devices, exposing employees to fire hazard.
Recent events (2)
- — I (O) $2000
- — Z (S) $8929
1910.305 G02 III
- Issued
- Sep 21, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. On or about June 2, 2023, at the establishment located at N4952 4th Street Leopolis, Wisconsin; the power cord for the APC SurgeArrest relocatable power tap did not have strain relief at the connection point exposing employees to fire hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.334 A03 I
- Issued
- Sep 21, 2023
- Abate by
- Nov 13, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment shall contain an equipment grounding conductor. On or about June 2, 2023, at the facility located at N4952 4th Street Leopolis, Wisconsin; the power cord on the Barnes Pumps, Inc. alarm system in garage was missing the ground pin exposing employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at U.S. Postal Service
View U.S. Postal Service's full OSHA safety record →
More inspections in this industry (NAICS 491110)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346743321.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.