OSHA Inspection: FIERY PLASTERING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FIERY PLASTERING in 2324 HIDDEN CREEK TRAIL, TYLER, TX 75703 (NAICS 238310). OSHA activity number 346743800.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fiery Plastering — free Get an email when a new federal OSHA severe-injury report for Fiery Plastering is published. One employer, no account, unsubscribe in one click.
Establishment
FIERY PLASTERING
Site address
2324 HIDDEN CREEK TRAIL
City
TYLER
State
TX
ZIP
75703
Mailing
5469 STATES HWY 43 EAST, HENDERSON, TX 75652
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.451 B01 I

Serious Gravity 5 2 instances 2 exposed
Issued
Jun 6, 2023
Abate by
Jul 3, 2023
Penalty
Initial $3,349 · Current $3,349
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary:  (a) On or about June 2, 2023, an employee working on the second tier of self-supported tubular welded end frame scaffolding built at the front of the house on the Westward side was not protected from a fall hazard of approximately thirteen (13) feet in that the scaffolding was not fully planked.  (b) On or about June 2, 2023, an employee working on the second tier of self-supported tubular welded end frame scaffolding built at the front of the house on the Eastward side was not protected from a fall hazard of approximately thirteen (13) feet in that the scaffolding was not fully planked.
Recent events (1)
  • — Z (S) $3349

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 6, 2023
Abate by
Jul 3, 2023
Penalty
Initial $4,688 · Current $4,688
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access:  (a) On or about June 3, 2023, at least one employee was accessing self-supported welded tubular end frame scaffolding by using the end frames and cross braces exposing them to a fall hazard of up to approximately thirteen (13) feet to the ground below.
Recent events (1)
  • — Z (S) $4688

1926.451 G01 VII

Serious Gravity 10 2 instances 2 exposed
Issued
Jun 6, 2023
Abate by
Jul 3, 2023
Penalty
Initial $4,688 · Current $4,688
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:  On or about June 2, 2023, employees working from the second tier of two sets of self-supported welded tubular end frame scaffolding set up at the front of the house were exposed to a fall hazard of approximately thirteen (13) feet in that:   (a) An employee and the employer were working from scaffolding set up on the westward side with no personal fall arrest or guardrail systems in use.   (b) An employee was working from scaffolding set up on the eastward side with no personal fall arrest or guardrail systems in use.