LOUISIANA, MO —
OSHA Inspection: NOVAE CORP.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NOVAE CORP. in 19790 U.S. 54, LOUISIANA, MO 63353 (NAICS 336390). OSHA activity number 346744758.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NOVAE CORP.
- Site address
- 19790 U.S. 54
- City
- LOUISIANA
- State
- MO
- ZIP
- 63353
- Mailing
- 19790 U.S. 54, LOUISIANA, MO 63353
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336390
- Employees
- 38
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.178 L01 I
- Issued
- Aug 8, 2023
- Abate by
- Sep 11, 2023
- Penalty
- Initial $10,938 · Current $6,563 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about 06/02/2023, the employer had not ensured that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training.
Recent events (2)
- — I (S) $6562.8
- — Z (S) $10938
1910.178 P01
- Issued
- Aug 8, 2023
- Abate by
- Sep 11, 2023
- Penalty
- Initial $10,938 · Current $6,563 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial trucks were found to be in need of repair, defective, or unsafe and were not taken out of service until they had been restored to safe operating condition. On or about 06/06/2023, the employer had not ensured any powered industrial truck which was found to be in need of repair, defective, or in any way unsafe, was removed from service. The following powered industrial trucks were in use and not removed from service: a) Toyota Forklift model 8FGU25 was defective at the time of the inspection. Two brake pads were missing exposing bare metal. b) HELI Forklift model CPC025-KU11 was defective at the time of the inspection. The horn and seatbelt were each not operable.
Recent events (2)
- — I (S) $6562.8
- — Z (S) $10938
1910.178 Q07
- Issued
- Aug 8, 2023
- Abate by
- Sep 11, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service at the start of each shift. On or about 06/02/2023 the employer had not ensured that each powered industrial truck was pre-inspected for safety compliance prior to use. The following powered industrial trucks were being operated for several months with unsafe conditions: a) Toyota propane model 8FGU25 had two missing brake pedal covers with bare metal exposed. b) HELI diesel model CPC025-KU11 had a non-functioning horn and seatbelt.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Aug 8, 2023
- Penalty
- Initial $6,250 · Current $3,750 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: On or about 06/02/23, the employer had not ensured that electrical protective covers were placed over an electrical outlet as well as an electrical light switch each located in the employees' office restroom.
Recent events (2)
- — I (S) $3750
- — Z (S) $6250
1910.147 C07 I
- Issued
- Aug 8, 2023
- Abate by
- Sep 11, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: On or about 06/02/2023, the employer had not provided their employees with Lock Out Tag Out training ensuring the ability to properly lock and tag out equipment in which electricity is supplied when maintenance is needed to repair or service.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Novae Corp.