Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DAC ELECTRICAL SERVICES, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of DAC ELECTRICAL SERVICES, LLC in 18802 W AIRPORT BOULEVARD, RICHMOND, TX 77407 (NAICS 238210). OSHA activity number 346746639.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch DAC Electrical Services, LLC — free Get an email when a new federal OSHA severe-injury report for DAC Electrical Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
18802 W AIRPORT BOULEVARD
City
RICHMOND
State
TX
ZIP
77407
Mailing
7926 ADCOCK ACRES DR, CONROE, TX 77303
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
12
Ownership type
A

2 citations on file for this inspection.

1926.651 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 17, 2023
Abate by
Aug 23, 2023
Penalty
Initial $3,572 · Current $1,786 Reduced
29 CFR  1926.651(c)(2):A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  (a) On or about June 2, 2023, at the jobsite where employees were digging an excavation, over 4 feet deep, with no means of egress.
Recent events (2)
  • — I (S) $1786
  • — Z (S) $3572

1926.651 J02

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 17, 2023
Abate by
Aug 23, 2023
Penalty
Initial $5,358 · Current $2,679 Reduced
29 CFR  1926.651(j)(2):Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.  (a)On or about June 2, 2023, at the jobsite, employees were digging inside of an excavation where the spoil pile was located less than 2 feet from the edge of the excavation.
Recent events (2)
  • — I (S) $2679
  • — Z (S) $5358

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346746639.