WEST HAVERSTRAW, NY —
OSHA Inspection: COSTAS CONSTRUCTION, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COSTAS CONSTRUCTION, INC. in 30 E. RAILROAD AVE., WEST HAVERSTRAW, NY 10993 (NAICS 238140). OSHA activity number 346748643.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COSTAS CONSTRUCTION, INC.
- Site address
- 30 E. RAILROAD AVE.
- City
- WEST HAVERSTRAW
- State
- NY
- ZIP
- 10993
- Mailing
- 401 SAW MILL RIVER ROAD, YONKERS, NY 10701
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B01
- Issued
- Jun 16, 2023
- Penalty
- Initial $4,688 · Current $4,688
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds should be fully planked or decked between the front uprights and the guardrail supports. On or about: May 31, 2023 Location: 30 E. Railroad Ave., West Haverstraw, NY 10993 a) Three (3) workers performing fa�ade repair on the volunteer firefighter house performed work on a tubular welded frame scaffold on a working level that was not fully planked or decked between the uprights.
Recent events (1)
- — Z (S) $4688
1926.451 B01 I
- Issued
- Jun 16, 2023
- Penalty
- Initial $4,688 · Current $4,688
General-duty citation text
29 CFR 1926.451(b)(1)(i):Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform). On or about: May 31, 2023 Location: 30 E. Railroad Ave., West Haverstraw, NY 10993 a)Three (3) workers performing fa�ade repair on the volunteer firefighter house performed work on a tubular welded frame scaffold while standing on scaffold planks with a space between the platforms greater than 1 inch.
Recent events (1)
- — Z (S) $4688
1926.451 B05 II
- Issued
- Jun 16, 2023
- Penalty
- Initial $3,349 · Current $3,349
General-duty citation text
29 CFR 1926.451(b)(5)(ii): Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. On or about: May 31, 2023 Location: 30 E. Railroad Ave., West Haverstraw, NY 10993 a) Three workers performing fa�ade repair on the volunteer firefighter house performed work on a tubular welded frame scaffold on a metal plank, used as a platform, that extended more than 18 inches over the support.