LEWISVILLE, TX —
OSHA Inspection: CONTRERAS MASONRY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CONTRERAS MASONRY in 801 LADY TESALA, LEWISVILLE, TX 75056 (NAICS 238140). OSHA activity number 346761216.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONTRERAS MASONRY
- Site address
- 801 LADY TESALA
- City
- LEWISVILLE
- State
- TX
- ZIP
- 75056
- Mailing
- 1242 N. JUSTIN AVE., DALLAS, TX 75211
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.100 A
- Issued
- Jul 28, 2023
- Abate by
- Aug 9, 2023
- Penalty
- Initial $2,679 · Current $1,607 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) This violation occurred on or about June 8, 2023, at a worksite located at 801 Lady Tesala, Lewisville, TX; where employees, who were working under construction activities, were not protected from head injuries by wearing hard hats.
Recent events (2)
- — I (S) $1607.4
- — Z (S) $2679
1926.451 E01
- Issued
- Jul 28, 2023
- Abate by
- Aug 9, 2023
- Penalty
- Initial $3,349 · Current $2,009 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: a) This violation occurred on or about June 8, 2023, at a worksite located at 801 Lady Tesala, Lewisville, TX; where employees, who were working from a scaffold system, climbed the end frame to access the work platform.
Recent events (2)
- — I (S) $2009.4
- — Z (S) $3349
1926.452 C02
- Issued
- Jul 28, 2023
- Abate by
- Aug 9, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(c)(2): Frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would secure vertical members together laterally: a) This violation occurred on or about June 8, 2023, at a worksite located at 801 Lady Tesala, Lewisville, TX; where employees, who were working from two-tier scaffold system that was missing cross bracing.
Recent events (2)
- — I (S) $0
- — Z (S) $0