Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GARDEN STATE HOME & LAWN SERVICE LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GARDEN STATE HOME & LAWN SERVICE LLC in 268 DUTCHMAN'S POINT ROAD, MANTOLOKING, NJ 08738 (NAICS 238990). OSHA activity number 346767221.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Garden State Home & Lawn Service LLC — free Get an email when a new federal OSHA severe-injury report for Garden State Home & Lawn Service LLC is published. One employer, no account, unsubscribe in one click.
Site address
268 DUTCHMAN'S POINT ROAD
City
MANTOLOKING
State
NJ
ZIP
08738
Mailing
16 ANNAPOLIS ROAD UNIT A2, TOMS RIVER, NJ 08757
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
6
Ownership type
A

5 citations on file for this inspection.

1926.451 C03

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 8, 2023
Abate by
Sep 14, 2023
Penalty
Initial $5,156 · Current $5,156
29 CFR  1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement:   a)  Back of Residential Structure, 268 Dutchman's Point Road, Brick Township NJ: Employees assisting with the installation of roof shingles, and other related activities, from a mixed component aluminum pump jack scaffold system were exposed to fall hazards when the three poles supporting the scaffold were visibly not plumb and level. One pole was out of plumb approximately 7 inches  over 44 inches of vertical height. Condition observed on or about 06/13/23.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $5156

1926.451 F03

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 8, 2023
Abate by
Sep 14, 2023
Penalty
Initial $5,156 · Current $5,156
29 CFR  1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:   a)  Back of Residential Structure, 268 Dutchman's Point Road, Brick Township NJ: Employees assisting with the installation of roof shingles, and other related activities, from a mixed component aluminum pump jack scaffold system that was not inspected for visible defects prior to beginning work were exposed to fall hazards up to and in excess of 22 feet to the ground surface below.  The scaffold's screen was not attached to the scaffold's walking and working surface its entire length, the scaffold's work rest was not connected to its supporting bracket, the poles of the scaffold were not braced properly and the scaffold's poles were not plumb.  Condition observed on or about 06/13/23.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $5156

1926.451 G04 IX

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 8, 2023
Abate by
Sep 14, 2023
Penalty
Initial $5,156 · Current $5,156
29 CFR  1926.451(g)(4)(ix): Midrails, screens, mesh, intermediate vertical members, soild panels, and equivalent structural members of a guardrail system were not capable of withstanding, without failure, a force to applied in any downward or horizontal direction at any point along the midrail or other member of at least 75 pounds for guardrail systems with a minimum 100 pound toprail capacity, and at least 150 pounds for guardrail systems with a minimum 200 pound toprail capacity:   a)  Back of Residential Structure, 268 Dutchman's Point Road, Brick Township NJ: Employees assisting with the installation of roof shingles, and other related activities, were exposed to fall hazards when working from a mixed component aluminum pump jack scaffold system whose midrail/screen of the scaffold was not secured to prevent displacement and was not capable of withstanding any force applied.  Condition observed on or about 06/13/23.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $5156

1926.452 J02

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 8, 2023
Abate by
Sep 14, 2023
Penalty
Initial $5,156 · Current $5,156
29 CFR  1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary:  a)  Back of Residential Structure, 268 Dutchman's Point Road, Brick Township NJ: Employees assisting with the installation of roof shingles, and other related activities, from a mixed component aluminum pump jack scaffold system were exposed to fall hazards when the three poles supporting the scaffold were only secured to the top of the structure with one brace each. Each of those braces was approximately 26 feet above ground level and being such this scaffold required additional bracing at its base.  Condition observed on or about 06/13/23.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $5156

1926.452 J03

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 8, 2023
Abate by
Sep 14, 2023
Penalty
Initial $5,156 · Current $5,156
29 CFR 1926.452(j)(3): When guardrails are used for fall protection, a workbench was used as the toprail which did not meet all the (guardrail) requirements in paragraphs (g)(4)(ii), (vii), (viii), and (xiii) of 1926.451:     a) Back side of residential structrure, 268 Dutchman's Point Road, Brick Township NJ:  The pump jack scaffold's workbench, consisting of an extended aluminum extension ladder, was not connected to its rest and was unable to withstand, without failure, a horizontal force.  Observed on or about 06/13/23.     NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $5156

View Garden State Home & Lawn Service LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346767221.