NORTH RICHLAND HILLS, TX —
OSHA Inspection: ACCURATE METAL STAMPING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ACCURATE METAL STAMPING in 7124 BELTON ST., NORTH RICHLAND HILLS, TX 76118 (NAICS 332119). OSHA activity number 346767932.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACCURATE METAL STAMPING
- Site address
- 7124 BELTON ST.
- City
- NORTH RICHLAND HILLS
- State
- TX
- ZIP
- 76118
- Mailing
- 7124 BELTON ST., NORTH RICHLAND HILLS, TX 76118
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332119
- Employees
- 82
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.37 A03
- Issued
- Aug 15, 2023
- Abate by
- Sep 13, 2023
- Penalty
- Initial $6,250 · Current $3,750 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not kept free and unobstructed. On or about June 13, 2023 and at times prior thereto, the facility exit routes were obstructed and blocked exposing employees to entrapment, trip and fall, and struck-by hazards in the following areas: a) in the cold saw cutting area - obstructed and blocked with metal storage material, work in process pallets, and fabricated door locking mechanisms welded to the inside of the exit door sticking out 9 inches. b) in the hand sanding room - blocked by a propane tank, a white board, a worktable, fans and stacks of pallets.
Recent events (2)
- — I (S) $3750
- — Z (S) $6250
1910.110 F02 II
- Issued
- Aug 15, 2023
- Abate by
- Sep 13, 2023
- Penalty
- Initial $6,250 · Current $3,750 Reduced
General-duty citation text
29 CFR 1910.110(f)(2)(ii): Liquid petroleum gas containers stored inside were located near exits, stairways, or in areas normally used or intended for the safe exit of people. On or about June 13, 2023, and times prior thereto, employees working in the hand sanding area were exposed to fire and explosion hazards when a liquid petroleum gas container was stored near the exit door/route.
Recent events (2)
- — I (S) $3750
- — Z (S) $6250
1910.110 F07
- Issued
- Aug 15, 2023
- Abate by
- Sep 13, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.110(f)(7): LP gas container storage location(s) were not provided with at least one approved portable fire extinguisher having a minimum rating of 8-B, C: On or about June 13, 2023, and at times prior thereto, the portable liquid petroleum storage area did not have suitable fire control devices, such as a portable fire extinguisher, exposing employees to fire and explosion hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 II
- Issued
- Aug 15, 2023
- Abate by
- Sep 13, 2023
- Penalty
- Initial $7,813 · Current $4,688 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): On or about June 13, 2023, and times prior thereto, energy control procedures did not include the specific steps for intended use of the procedure(s), ensuring the responsibilities for the control of energy and the lock out devices, and the requirements to test/enforce the effectiveness of the energy control measures exposing employees to the hazards of unexpected energization, start-up of machinery and/or equipment, or release of stored energy.
Recent events (2)
- — I (S) $4687.8
- — Z (S) $7813
1910.212 A01
- Issued
- Aug 15, 2023
- Abate by
- Sep 13, 2023
- Penalty
- Initial $6,250 · Current $3,750 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. On or about June 13, 2023, and at times prior thereto, employees operating machines were exposed to being struck-by and caught-in rotating parts due to lack of machine guarding in the following instances: a) in the assembly area, the Grizzly Industrial drill press point of operation and missing covers over the drive belts. b) in the saw area, two horizontal Klutch band saws did not have unused portions of the blades guarded.
Recent events (2)
- — I (S) $3750
- — Z (S) $6250
1910.253 B04 III
- Issued
- Aug 15, 2023
- Abate by
- Sep 13, 2023
- Penalty
- Initial $7,813 · Current $4,688 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. On or about June 13, 2023, and times prior thereto, in the welding department, employees were exposed to fire and explosion hazards when the oxy-acetylene cylinders in storage were not protected by a noncombustible barrier at least 5 feet high with a fire resistance rating of at least one-half hour.
Recent events (2)
- — I (S) $4687.8
- — Z (S) $7813
1910.303 B02
- Issued
- Aug 15, 2023
- Abate by
- Sep 13, 2023
- Penalty
- Initial $6,250 · Current $3,750 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling. On or about June 13, 2023, and times prior thereto, electrical equipment was used or installed in accordance with manufacturers design and listing and labeling requirements exposing employees to electric shock in the following instances: a) in the PEG area, a conductive electrical outlet box was used with flexible cord to power hand tools, a floor fan and a stereo. b) in the saw area, along the East wall, a floor fan was plugged into a conductive electric outlet box spliced with a flexible cord. c) in the saw area, a 4-way conductive electrical box was used to power two Klutch horizontal band saws, 240 volts.
Recent events (2)
- — I (S) $3750
- — Z (S) $6250
1910.303 G01
- Issued
- Aug 15, 2023
- Abate by
- Sep 13, 2023
- Penalty
- Initial $9,376 · Current $5,626 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: On or about June 13, 2023, and at times prior thereto, 240v and 480v circuit breaker panels and electrical disconnect panels were obstructed preventing safe access in the event of an emergency creating struck-by, caught-in and electric shock hazards in the following instances: a) In the Tube laser area, the panels were blocked. b) In the Pega machine area, the panels were blocked. c) In the pemsert hardware install area, the panels were blocked.
Recent events (2)
- — I (S) $5625.6
- — Z (S) $9376
1910.37 B02
- Issued
- Aug 15, 2023
- Abate by
- Sep 13, 2023
- Penalty
- Initial $877 · Current $526 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit" On or about June 13, 2023, and times prior thereto, the facility exit routes lacked required signage exposing employees to smoke inhalation, asphyxiation, and entrapment hazards in the following areas: a) in the hand sanding area. b) the north end of the plant floor going into the front offices. c) the shipping area going into the front offices.
Recent events (2)
- — I (O) $526.2
- — Z (O) $877
1910.305 G01 IV A
- Issued
- Aug 15, 2023
- Abate by
- Sep 13, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. On June 13, 2023, and times prior thereto, extension cords, wrapped around metal conduit, was used as permanent wiring to energize cameras in the paint area exposing employees to electrical shock and fire hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332119)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346767932.