GONZALES, LA —
OSHA Inspection: SYSTEM SERVICES PIPELINE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SYSTEM SERVICES PIPELINE in HWY 621 AND AIRLINE HWY, GONZALES, LA 70707 (NAICS 237120). OSHA activity number 346770696.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SYSTEM SERVICES PIPELINE
- Site address
- HWY 621 AND AIRLINE HWY
- City
- GONZALES
- State
- LA
- ZIP
- 70707
- Mailing
- 298 TOWER ROAD, PONCHATOULA, LA 70454
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237120
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.651 C02
- Issued
- Sep 14, 2023
- Penalty
- Initial $7,813 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp, or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in-depth so as to require no more than 25 feet (7.62m) of lateral travel for employees. On or about June 14, 2023, on the south side of the site, an employee was performing pipeline repair without a means of safe egress from an excavation four (4) feet or more in-depth.
Recent events (3)
- — J (S) $0
- — C (S) $7813
- — Z (S) $7813
1926.652 A01
- Issued
- Sep 14, 2023
- Abate by
- Sep 29, 2023
- Penalty
- Initial $9,376 · Current $0 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). On or about June 14, 2023, employees installed/repaired a utility pipe in an excavation five (5) feet or more in-depth without cave-in protection.
Recent events (3)
- — J (S) $0
- — C (S) $9376
- — Z (S) $9376
More inspections at System Services Pipeline
View System Services Pipeline's full OSHA safety record →
More inspections in this industry (NAICS 237120)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346770696.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.