Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BRIDGEPOINT ELECTRIC, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BRIDGEPOINT ELECTRIC, INC. in 9607 S. MEMORIAL DRIVE, TULSA, OK 74133 (NAICS 238210). OSHA activity number 346772718.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bridgepoint Electric, INC. — free Get an email when a new federal OSHA severe-injury report for Bridgepoint Electric, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9607 S. MEMORIAL DRIVE
City
TULSA
State
OK
ZIP
74133
Mailing
171 S. 122ND E. AVE, TULSA, OK 74128
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
110
Ownership type
A

2 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 27, 2023
Penalty
Initial $8,036 · Current $4,822 Reduced
29 CFR  1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns.   On or about June 15, 2023,  employees were working in a excavation and were not in use of head protection.  This exposed the employees to a struck-by hazard.
Recent events (2)
  • — I (S) $4821.6
  • — Z (S) $8036

1926.651 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 27, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.   On or about June 15, 2023,  employees were working in a excavation next to the the spoil pile with unsecured concrete blocks.  This exposed the employees to a struck-by hazard.