CINCINNATI, OH —
OSHA Inspection: S2K EXCAVATING LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of S2K EXCAVATING LLC in 866 EASTGATE NORTH DR., CINCINNATI, OH 45245 (NAICS 237110). OSHA activity number 346773492.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- S2K EXCAVATING LLC
- Site address
- 866 EASTGATE NORTH DR.
- City
- CINCINNATI
- State
- OH
- ZIP
- 45245
- Mailing
- 9385 PEARSON RD., WEST MILTON, OH 45383
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 9
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.651 C02
- Issued
- Aug 22, 2023
- Penalty
- Initial $4,688 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.651(c)(2):Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees. a) On June 15, 2023, the employer failed to ensure that a stairway, ladder, ramp, or other safe means of egress was provided for employees working in a trench excavation that was between 7 and 8 feet in depth. As a result, employees working in the trench were exposed to the hazards of delayed egress in the event of an accident or emergency.
Recent events (2)
- — I (S) $1500
- — Z (S) $4688
1926.652 A01
- Issued
- Aug 22, 2023
- Penalty
- Initial $4,688 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.652(a)(1):Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when: -Excavations are made entirely in stable rock; or -Excavations are less than 5 feet (1.52m) in depth and examination of the ground by a competent person provides no indication of a potential cave-in. a.) On June 15, 2023, the employer failed to ensure that employees were protected from cave-in hazards by an adequate protective system in that, employees were found working in a trench, outside of the trench shield, without cave-in protection. The trench measured up to 8' deep, with straight vertical sidewalls.
Recent events (2)
- — I (S) $1500
- — Z (S) $4688
More inspections in this industry (NAICS 237110)