Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A & A QUALITY APPLIANCE, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of A & A QUALITY APPLIANCE, INC. in 321 W 84TH AVE, THORNTON, CO 80260 (NAICS 493110). OSHA activity number 346774268.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A & a Quality Appliance, INC. — free Get an email when a new federal OSHA severe-injury report for A & a Quality Appliance, INC. is published. One employer, no account, unsubscribe in one click.
Site address
321 W 84TH AVE
City
THORNTON
State
CO
ZIP
80260
Mailing
321 W 84TH AVE, THORNTON, CO 80260
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
120
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 1, 2023
Abate by
Dec 27, 2023
Penalty
Initial $9,488 · Current $6,000 Reduced
Section 5(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards:  (a)	On or about June 15, 2023, employees were required to store, add, and pick heavy items such as washing machines, clothes dryers, and microwave ovens from storage racks that five levels high.  The storage rack system is made up of steel structural members in the form of a frame, post, and beams to form a bay.  Two separate vertical posts on different rows had been struck by equipment and were damaged and bent near the work floor.  This condition exposed employees to struck-by hazards.  Feasible and acceptable abatement methods include, but are not limited to:  1)	Conduct regular visual inspections of the racking system to identify damaged and/or bent structural framing and fix as needed.  2)	Install physical barriers near row ends to prevent forklifts and other mechanized equipment from damaging vertical rack posts.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $9488

1910.151 C

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Dec 1, 2023
Abate by
Dec 7, 2023
Penalty
Initial $7,590 · Current $2,600 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  (a)	On or about June 15, 2023, the employer did not provide suitable facilities for quick drenching or flushing of the eyes in the forklift battery charging area in that the plumbed-in eyewash was blocked by a metal bailing machine and was not accessible for use.  Corrosive buildup was located on the plastic casing of the Interstate Batteries 24-volt battery used in the Picker Raymond-5 and on the plastic casing of the battery RPB922340 used on the Crown forklift-1.  This condition exposed employees to serious eye injuries and damage.
Recent events (2)
  • — I (O) $2600
  • — Z (S) $7590

1910.303 F02

Other-than-serious 1 instance 3 exposed
Issued
Dec 1, 2023
Abate by
Dec 11, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means, or over current device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  (a)	On or about June 15, 2023, the employer did not ensure each circuit breaker in panel L1S and in panel H1S was identified.  The two panels were located inside the facility near the shipping and receiving area.  Several of the circuit breakers were not marked to indicate its purpose.  This condition potentially exposed the employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346774268.