Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARMANDO D. ORTEGA DBA ADO RENOVATIONS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARMANDO D. ORTEGA DBA ADO RENOVATIONS in 632 N ARLINGTON HEIGHTS RD, ARLINGTON HEIGHTS, IL 60004 (NAICS 238160). OSHA activity number 346774458.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Armando D. Ortega DBA ADO Renovations — free Get an email when a new federal OSHA severe-injury report for Armando D. Ortega DBA ADO Renovations is published. One employer, no account, unsubscribe in one click.
Site address
632 N ARLINGTON HEIGHTS RD
City
ARLINGTON HEIGHTS
State
IL
ZIP
60004
Mailing
38763 N. LEWIS AVE., BEACH PARK, IL 60099
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
11
Ownership type
A

8 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Oct 12, 2023
Abate by
Nov 7, 2023
Penalty
Initial $501 · Current $501
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  Armando D. Ortega dba ADO Renovations, failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:  Citation Number                Item Number                        Abatement Date 01                                              03                                              08/03/2023  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $501

1926.102 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 10, 2023
Penalty
Initial $5,358 · Current $5,358
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:     a) On June 15, 2023, employees were exposed to eye injury while operating a pneumatic nail gun without eye protection during roofing work.  No abatement certification or documentation is required for this item.
Recent events (1)
  • — Z (S) $5358

1926.451 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 10, 2023
Penalty
Initial $4,465 · Current $4,465
29 CFR 1926.451(e)(1): Safe access was not provided to scaffold platforms when the platforms were more than 2 feet above or below the point of access:  a)  On June 15, 2023 employees were exposed to a fall hazard of approximately 17.2 feet while accessing a ladder jack scaffold.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $4465

1926.451 F06

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 10, 2023
Abate by
Aug 3, 2023
Penalty
Initial $6,250 · Current $6,250
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6):  a) On June 15, 2023 employees were exposed to electrical hazards while erecting, dismantling, and working from frame scaffolding in close proximity to a 120/240 volt overhead power line.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $6250

1926.451 G01 I

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 10, 2023
Penalty
Initial $6,250 · Current $6,250
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:  a)  On June 15, 2023 employees working from a ladder jack scaffold were exposed to a fall hazard of approximately 17.2 feet.  No abatement certification or documentation is required for this item.
Recent events (1)
  • — Z (S) $6250

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
Jul 10, 2023
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a)  On June 15, 2023 employees performing roofing work were exposed to fall hazards of approximately 17.2 feet.  No abatement certification or documentation is required for this item.
Recent events (1)
  • — Z (S) $0

1926.452 K05

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 10, 2023
Penalty
Initial $6,250 · Current $6,250
29 CFR 1926.452(k)(5):  Scaffold platforms were bridged one to another:    a)  On June 15, 2023 employees were exposed to fall hazards of approximately 17.2 feet while using a ladder jack scaffold with bridged platforms.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $6250

1926.1053 B04

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 10, 2023
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4):  Ladder(s) were used for purposes other than the purpose for which they were designed:  a)  On June 15, 2023, the fly section of an extension ladder was used as platform to bridge a scaffold.    No abatement certification or documentation is required for this item.
Recent events (1)
  • — Z (S) $0

View Armando D. Ortega DBA ADO Renovations's full OSHA safety record →