Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FEDERAL TRADE COMMISSION, NORTHWEST REGION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FEDERAL TRADE COMMISSION, NORTHWEST REGION in 915 SECOND AVE, SUITE 2896, SEATTLE, WA 98174 (NAICS 922130). OSHA activity number 346775190.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Federal Trade Commission, Northwest Region — free Get an email when a new federal OSHA severe-injury report for Federal Trade Commission, Northwest Region is published. One employer, no account, unsubscribe in one click.
Site address
915 SECOND AVE, SUITE 2896
City
SEATTLE
State
WA
ZIP
98174
Mailing
915 SECOND AVE, SUITE 2896, SEATTLE, WA 98174
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
922130
Employees
22
Ownership type
D

1 citation on file for this inspection.

1910.304 B04 II B

Serious Gravity 5 1 instance 22 exposed
Issued
Aug 21, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle supplied a total cord- and plug-connected load in excess of the maximum specified in Table S-4:  A)     In the office break room, there was a single 15-amp power strip with a toaster, hot water heater, and coffee maker plugged into it.  The power strip was plugged into a 15-amp outlet in the wall connected to a 20-amp branch circuit.  The total current load on the outlet and the power strip was 28.75 amps, exceeding the maximum amount of current that could safely flow through the outlet, the power strip, and the branch circuit.