PHILADELPHIA, PA —
OSHA Inspection: GEMINI BAKERY EQUIPMENT CO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GEMINI BAKERY EQUIPMENT CO in 9990 GANTRY ROAD, PHILADELPHIA, PA 19115 (NAICS 333241). OSHA activity number 346775877.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GEMINI BAKERY EQUIPMENT CO
- Site address
- 9990 GANTRY ROAD
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19115
- Mailing
- 9990 GANTRY ROAD, PHILADELPHIA, PA 19115
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333241
- Employees
- 62
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 14, 2023
- Abate by
- Jan 4, 2024
- Penalty
- Initial $14,063 · Current $9,844 Reduced
General-duty citation text
Alleged Violation Description OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to struck-by hazards associated with inadequately maintained racking systems: (a) Jobsite: 9990 Gantry Road, Philadelphia, PA 19115 - On or about June 16, 2023, the employer did not ensure steel racking system used to store pallets with cardboard boxes containing parts was secured with floor and wall anchors, exposing employees to a struck-by hazard when they operated forklifts to load and unload equipment on to the racks and when employees are walking near the racks.
Recent events (2)
- — I (S) $9844.1
- — Z (S) $14063
1910.101 B
- Issued
- Dec 14, 2023
- Abate by
- Jan 4, 2024
- Penalty
- Initial $6,026 · Current $0 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6 Section 3.3.1 of the CGA Pamphlet P-1-1965 refers to storing cylinders in accordance with CGA and NFPA standards. The CGA Pamphlet P-1-1991 Section 3.7.4.1 states that "All compressed gas cylinders in service or in storage shall be secured to prevent from falling." (a) Jobsite: 9990 Gantry Road, Philadelphia, PA 19115 - On or about June 16, 2023, the employer did not ensure that the storage of compressed gas cylinders, such as an approximately 8lb cylinder containing Argon, was immobilized by chains or other means to prevent from being knocked over, thereby exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $6026
1910.106 E09 III
- Issued
- Dec 14, 2023
- Penalty
- Initial $8,036 · Current $5,625 Reduced
General-duty citation text
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: (a) Jobsite: 9990 Gantry Road, Philadelphia, PA 19115 - On or about June 16, 2023, the employer did not ensure soaked rags used for absorbing oils were stored in covered metal receptacles and/or disposed daily. Employees stored oil soaked rags in a cardboard box.
Recent events (2)
- — I (S) $5625.2
- — Z (S) $8036
1910.106 D03 II A
- Issued
- Dec 14, 2023
- Penalty
- Initial $8,036 · Current $5,625 Reduced
General-duty citation text
29 CFR 1910.106(d)(3)(ii)(a): Metal storage cabinets construction. The bottom, top, door, and sides of cabinet were not at least No. 18 gage sheet iron and double walled with 1 1/2 - inch air space. Joints were not riveted, welded or made tight by some equally effective means. The door was not provided with a three-point lock, and the door sill was not raised at least 2 inches above the bottom of the cabinet. (a) Jobsite: 9990 Gantry Road, Philadelphia, PA 19115 - On or about June 16, 2023, the employer did not ensure a metal storage cabinet containing flammable liquids such as, but not limited to acetone, paint thinner, etc. were not constructed with 18 gage sheet iron and double walled with 1 and 1 half inch air space. The metal storage cabinet doors were constructed with perforated sheet metal.
Recent events (2)
- — I (S) $5625.2
- — Z (S) $8036
1910.212 A01
- Issued
- Dec 14, 2023
- Penalty
- Initial $10,046 · Current $7,032 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. (a) Jobsite: 9990 Gantry Road, Philadelphia, PA 19115 - On or about June 16, 2023: The employer did not ensure that the rotating part of the machine was guarded to prevent employee exposure from such hazard. An employee engaged in polishing metals on the Machine Tool Division MSC 16-50G GAP Bed Lathe in the area of the unguarded chuck was exposed to the rotating parts.
Recent events (2)
- — I (S) $7032.2
- — Z (S) $10046
More inspections in this industry (NAICS 333241)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346775877.