On , OSHA opened a complaint safety inspection of GENERAL PARTITIONS MANUFACTURING CORP. in 2424 WEST 23RD STREET, ERIE, PA 16506 (NAICS 337215). OSHA activity number 346779291.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch General Partitions Manufacturing Corp. — free Get an email when a new federal OSHA severe-injury report for General Partitions Manufacturing Corp. is published. One employer, no account, unsubscribe in one click.
Site address
2424 WEST 23RD STREET
City
ERIE
State
PA
ZIP
16506
Mailing
1702 PENINSULA DRIVE, ERIE, PA 16505
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337215
Employees
57
Ownership type
A

6 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 27, 2023
Abate by
Oct 24, 2023
Penalty
Initial $5,313 · Current $5,000 Reduced
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a.)  General Partitions Manufacturing Corp.;   2424 W. 23rd Street, Erie, PA - On or about 6/20/23, and at times prior thereto,  the company had not performed periodic inspections of the energy control/lockout tagout procedures. Employees conducted servicing, maintenance and repair on equipment that included, but was not limited to, the Edge Bander.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $5313

1910.147 C07 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 27, 2023
Abate by
Oct 24, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:   a.) General Partitions Manufacturing Corp; 2424 W. 23rd Street, Erie, PA - On or about 6/20/23, and at times prior thereto, the company had not provided lockout/tagout training on the employer's energy control/lockout tagout procedures and program for authorized employees. Employees conducted servicing and maintenance on equipment, including, but not limited to, the Edge Bander.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I B

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 27, 2023
Abate by
Oct 24, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i)(B): Affected employee(s) was not instructed in the purpose and use of the energy control procedure.   a.) General Partitions Manufacturing Corp;  2424 W. 23rd Street, Erie, PA - On or about 6/20/23, and at times prior thereto, the company had not provided lockout/tagout training on the employer's energy control/lockout tagout procedures and program for affected employees.   Employees performed servicing and maintenance on equipment including, but not limited to, Edge Bander and conveyor.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L01 II

Serious Gravity 10 1 instance 10 exposed
Issued
Sep 27, 2023
Abate by
Oct 24, 2023
Penalty
Initial $10,938 · Current $7,000 Reduced
29 CFR  1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck   a.) General Partitions Manufacturing Corp.; 2424 W. 23rd Street- On or about 6/20/23, and at times prior thereto, the company was permitting the employees to operate forklifts without being trained on the forklifts. Employees used forklifts to move stacks of materials in the facility.  The propane forklifts included, but were not limited to, Hyster, CAT, and Yale.    ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation.  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement. IN ADDITION, abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic, or video evidence or abatement or other written records.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $10938

1910.178 L04 II B

Deleted Serious Gravity 5 1 instance 10 exposed
Issued
Sep 27, 2023
Abate by
Oct 24, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.178(l)(4)(ii)(B): Refresher training in relevant topics shall be provided to the operator when the operator has been involved in an accident or near-miss;    a.) General Partitions Manufacturing Corp.; 2424 W. 23rd Street, Erie, PA- On or about 6/20/23, and at times prior thereto, the employer did not retrain and reevaluate the forklift operators after near misses or accidents.  Forklifts operated by employees included, but were not limited to, CAT, Hyster, and Yale.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B01 V

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Sep 27, 2023
Abate by
Oct 24, 2023
Penalty
Initial $5,313 · Current $0 Reduced
29 CFR  1910.303(b)(1)(v):Safety of electrical equipment was not determined by considering heating effects under all conditions of use.  a.)  General Partitions Manufacturing Corp.-; 2424 W. 233rd Street, Erie, PA  -  On or about 6/20/23, and at times prior thereto, The Edge Bander computer control box was overheating due to the fan inside the box not working.  The box was propped open to keep the box cool while the Edge Bander was in operation.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (S) $5313