Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THAXTON ROOFING & TINNING CO. INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THAXTON ROOFING & TINNING CO. INC. in 20631 STRATFORD DRIVE, ROCKY RIVER, OH 44116 (NAICS 238160). OSHA activity number 346783822.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Thaxton Roofing & Tinning CO. INC. — free Get an email when a new federal OSHA severe-injury report for Thaxton Roofing & Tinning CO. INC. is published. One employer, no account, unsubscribe in one click.
Site address
20631 STRATFORD DRIVE
City
ROCKY RIVER
State
OH
ZIP
44116
Mailing
3357 ARBOR WAY, WESTLAKE, OH 44145
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

2 citations on file for this inspection.

1926.1053 B01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Jun 30, 2023
Penalty
Initial $3,683 · Current $0 Reduced
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   On or about June 22, 2023 employees were exposed to a fall hazard of approximately 20 feet while performing roofing activities on a residential home located at 20631 Stratford Drive, Westlake, OH . Employees were using an extension ladder to access the roof and the employer did not ensure they extended at least 3 feet above the upper landing surface.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3683

1926.501 B13

Deleted Repeat Gravity 5 1 instance 3 exposed
Issued
Jun 30, 2023
Abate by
Jul 21, 2023
Penalty
Initial $7,367 · Current $0 Reduced
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) Thaxton Roofing & Tinning Co. Inc., on or about June 22, 2023, at the location of 20631 Stratford Drive, Rocky River, OH: The employer did not ensure that employees performing roofing activities on a steep roof were protected from fall hazards. Employees were exposed to fall hazards of 20-22 feet to the ground below while performing roofing activities.  Thaxton Roofing & Tinning Co. Inc. was previously cited for a violation of this occupational safety and health standard  29 CFR  1926.501(b)(13), which was contained in OSHA inspection number 1536071, citation number 1, item number 1 and was affirmed as a final order on 7/26/2021, with respect to a workplace located at 2326 Ogontz Ave., Lakewood, OH 44107 .
Recent events (2)
  • — I (R) $0
  • — Z (R) $7367

View Thaxton Roofing & Tinning CO. INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346783822.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.