MOUNTAIN HOME, TN —
OSHA Inspection: AFCI-CCI JV ONE, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AFCI-CCI JV ONE, LLC in S. FIRST STREET BLDG. 20, MOUNTAIN HOME, TN 37684 (NAICS 236220). OSHA activity number 346784796.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AFCI-CCI JV ONE, LLC
- Site address
- S. FIRST STREET BLDG. 20
- City
- MOUNTAIN HOME
- State
- TN
- ZIP
- 37684
- Mailing
- 837 OAKTON STREET, ELK GROVE VILLAGE, IL 60007
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 1
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.350 A07
- Issued
- Aug 30, 2023
- Penalty
- Initial $7,813 · Current $3,907 Reduced
General-duty citation text
29 CFR 1926.350(a)(7): A suitable cylinder truck, chain, or other steadying device was not used to keep compressed gas cylinder(s) from being knocked over while in use: (a) Storage container, North side of building exterior: On or about June 21, 2023, and at times prior, the employer exposed employees to struck by hazards, in that a 120CF oxygen cylinder was not secured to prevent it from being knocked over in an area that was frequented by multiple employees from multiple sub-contractors while they retrieved supplies from the storage container.
Recent events (3)
- — F (O) $3906.5
- — C (S) $7813
- — Z (S) $7813
1926.405 G02 III
- Issued
- Aug 30, 2023
- Abate by
- Sep 12, 2023
- Penalty
- Initial $9,376 · Current $4,688 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iii): The repair splice in a hard service flexible cord No. 12 or larger did not retain the insulation, outer sheath properties, and usage characteristics of the cord which was being used: (a) 2nd floor, North west room, on wall to left of door: On or about 21 June 2023, and at times prior, the employer exposed employees to fire and electrical shock hazards in that a Southwire SJTW Plastic Guard Sting Light was spliced together and covered with electrical tape after being completely severed. (a) 1st floor, North west room, on floor next to doorway on left: On or about 21 June 2023, and at times prior, the employer exposed employees to fire and electrical shock hazards in that a Southwire SJTW Plastic Guard Sting Light was severed and the end repaired incorrectly with electrical tape.
Recent events (3)
- — F (O) $4688
- — C (S) $9376
- — Z (S) $9376
1926.501 C03
- Issued
- Aug 30, 2023
- Penalty
- Initial $10,938 · Current $5,469 Reduced
General-duty citation text
29 CFR 1926.501(c)(3): The employer did not barricade the area to which objects could fall, did not prohibit employees from entering the barricaded area, and did not keep objects that could fall far enough away from the edge of a higher level so that the objects would not go over the edge if they were accidentally displaced. (a) 2nd floor, North-West room, window: On or about June 21, 2023, and at times prior, the employer exposed employees to possible death or severe head injuries, in that, a Rigid R86001 18V 1/2 Drill/Driver with battery and bit installed (3.79lbs), 16oz claw hammer, 12 inch steel pry bar, aluminum square, shims, Philips screwdriver, and a box of 2 1/2 inch nails, were left sitting unsecured on the sill of an open window located directly above the employee break/sitting area where individuals were sitting without hard hats.
Recent events (3)
- — F (O) $5469
- — C (S) $10938
- — Z (S) $10938
1926.150 A02
- Issued
- Aug 30, 2023
- Penalty
- Initial $877 · Current $0 Reduced
General-duty citation text
29 CFR 1926.150(a)(2): Access to all available firefighting equipment was not maintained at all times: (a) Bldg. 20, bottom landing of interior stairwell: On or about June 21st 2023, and at times prior, the employer exposed employees to fire related hazards, in that a mounted, portable fire extinguisher was not readily available for use because it was being used as a hanger for a safety face shield.
Recent events (3)
- — F (O) $0
- — C (O) $877
- — Z (O) $877
More inspections in this industry (NAICS 236220)
More inspections in TN
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346784796.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.