MOUNTAIN HOME, TN —
OSHA Inspection: BELTLINE ELECTRIC COMPANY, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of BELTLINE ELECTRIC COMPANY, INC. in S. FIRST STREET BLDG. 20, MOUNTAIN HOME, TN 37684 (NAICS 238210). OSHA activity number 346784812.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BELTLINE ELECTRIC COMPANY, INC.
- Site address
- S. FIRST STREET BLDG. 20
- City
- MOUNTAIN HOME
- State
- TN
- ZIP
- 37684
- Mailing
- 2701 WAYNE SULLIVAN DRIVE, PADUCAH, KY 42003
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.405 G02 III
- Issued
- Aug 31, 2023
- Abate by
- Sep 13, 2023
- Penalty
- Initial $7,813 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iii): The repair splice in a hard service flexible cord No. 12 or larger did not retain the insulation, outer sheath properties, and usage characteristics of the cord which was being used: (a) 2nd floor, North west room, on wall to left of door: On or about 21 June 2023, and at times prior, the employer exposed employees to fire and electrical shock hazards in that a Southwire SJTW Plastic Guard Sting Light was spliced together and covered with electrical tape after being completely severed. (b) 1st floor, North west room, on floor next to doorway on left: On or about 21 June 2023, and at times prior, the employer exposed employees to fire and electrical shock hazards in that a Southwire SJTW Plastic Guard Sting Light was severed and the end repaired incorrectly with electrical tape.
Recent events (3)
- — F (S) $0
- — C (S) $7813
- — Z (S) $7813
1926.150 A02
- Issued
- Aug 31, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.150(a)(2): Access to all available firefighting equipment was not maintained at all times: (a) Bldg. 20, bottom landing of interior stairwell: On or about June 21, 2023, and at times prior, the employer exposed employees to fire related hazards in that a mounted fire extinguisher was not readily available because a clear face shield was hanging on it.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238210)
More inspections in TN
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346784812.