Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HEARTHSIDE FOOD SOLUTIONS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HEARTHSIDE FOOD SOLUTIONS, LLC in 720 CENTER AVE., CAROL STREAM, IL 60188 (NAICS 311999). OSHA activity number 346784846.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hearthside Food Solutions, LLC — free Get an email when a new federal OSHA severe-injury report for Hearthside Food Solutions, LLC is published. One employer, no account, unsubscribe in one click.
Site address
720 CENTER AVE.
City
CAROL STREAM
State
IL
ZIP
60188
Mailing
720 CENTER AVE., CAROL STREAM, IL 60188
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311999
Employees
900
Ownership type
A

5 citations on file for this inspection.

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 14, 2023
Abate by
Mar 18, 2024
Penalty
Initial $15,625 · Current $10,000 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedure) was not done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6):  On or about August 11, 2023, the employer did not ensure that Sanitation employees implemented energy control application steps prior to allowing them to engage in servicing and maintenance activities on while performing the "Dry Cleaning" in the "Secondary" production rooms exposing them to pinch/nip point hazards and amputation injuries.   As a result, the following steps were not implemented in order involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $10000
  • — Z (S) $15625

1910.212 A01

Serious Gravity 10 1 instance 500 exposed
Issued
Dec 14, 2023
Abate by
Jan 16, 2024
Penalty
Initial $15,625 · Current $10,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.  On or about July 10, 2023, the employer did not provide one or more methods of machine guarding to protect employees working along the CS-1 line. Employees were exposed to caught-in nip point hazards due to the gaps present in the slatted conveyor belt, which could result in injuries such as abrasions, lacerations, crushing or amputation injuries.   Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $10000
  • — Z (S) $15625

1910.303 B01

Serious Gravity 10 2 instances 150 exposed
Issued
Dec 14, 2023
Abate by
Jan 16, 2024
Penalty
Initial $15,625 · Current $10,000 Reduced
29 CFR 1910.303(b)(1): Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees.   On or about June 22, 2023, the employer had two instances in the main forklift battery charging room which electrical equipment was not free from recognized hazards exposing employees to electrical shock hazards. The following instances were observed:  (a) On or about June 22, 2023, there was an electrical box on the wall in the main forklift battery charging room that was damaged. The box was bent in, and the cover was not secured, exposing employees to electrical shock hazards.  (b) On or about June 22, 2023, there was battery charging with a damaged power connector/plug in the main forklift battery charging room, exposing employees to electrical shock hazards. This battery sat directly below a sign that said, "BATTERY 21."  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $10000
  • — Z (S) $15625

1910.303 B07 I

Serious Gravity 10 4 instances 933 exposed
Issued
Dec 14, 2023
Abate by
Jan 16, 2024
Penalty
Initial $15,625 · Current $10,000 Reduced
29 CFR 1910.303 (b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.  On or about June 22, 2023, there were multiple locations observed to have unused openings in electrical boxes that were not effectively closed exposing employees to electrical shock injuries and electrocution.  The following instances were observed: (a) A metal wall mounted square box coming off 480V Panel B4B labeled "UPS-DP CKTS 13-15-17, 19-21-23, 25-27-29" was damaged in the forklift charging room with unused openings not effectively closed.  (b) A metal wall mounted square box coming off 480V Panel B4B labeled "UPS-DP CKTS 26-28-30" in the forklift charging room with unused openings not effectively closed.  (c) A metal wall mounted square box labeled "PANEL VRP 1 CIRCUIT 14" observed near a satellite forklift charging area with unused openings not effectively closed.  (d) A metal wall mounted square box labeled "PANEL VRP 1 CIRCUIT 16" observed near a satellite forklift charging area with unused openings not effectively closed.  (e) A metal wall mounted square box labeled "PANEL VRP 1 CIRCUIT 18" observed near a satellite forklift charging area with unused openings not effectively closed.  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $10000
  • — Z (S) $15625

1910.303 G01

Serious Gravity 10 6 instances 3 exposed
Issued
Dec 14, 2023
Abate by
Jan 16, 2024
Penalty
Initial $15,625 · Current $10,000 Reduced
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.  On or about September 7, 2023, there was insufficient working space for 480V switches in the ammonia refrigeration equipment room. Obstructed access to electrical equipment can prevent personnel from shutting down the source of power in the event of an emergency exposing employees to increases risk of injuries that could be fatal.    The following instances were observed: (a)  EF-1 480V Switch blocked by "AMMONIA WASTE" drum/barrel. (b) EF-2 480V Switch blocked by stacked buckets and stacked bins. (c) EF-3 480V Switch blocked by buckets and what appeared to be a spare pump/motor. (d) Allen-Bradley PowerFlex West Fan Control module blocked by barrel with quick dry mats stacked on top. (e) Allen-Bradley PowerFlex West Fan Control module blocked by barrel with quick dry mats stacked on top. (f) Allen-Bradley PowerFlex West Fan Control module blocked by "AMMONIA WASTE" drum/barrel.  Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $10000
  • — Z (S) $15625

View Hearthside Food Solutions, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346784846.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.