OSHA Inspection: U.S. POSTAL SERVICE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. POSTAL SERVICE in 189 WASHINGTON STREET, HARTFORD, CT 06106 (NAICS 491110). OSHA activity number 346785736.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Postal Service — free Get an email when a new federal OSHA severe-injury report for U.S. Postal Service is published. One employer, no account, unsubscribe in one click.
Establishment
U.S. POSTAL SERVICE
Site address
189 WASHINGTON STREET
City
HARTFORD
State
CT
ZIP
06106
Mailing
67 BEAVER BROOK ROAD, WETHERSFIELD, CT 06109
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
491110
Employees
70
Ownership type
A

9 citations on file for this inspection.

1910.37 A04

Other-than-serious Gravity 1 2 instances 4 exposed
Issued
Aug 15, 2023
Abate by
Oct 2, 2023
Penalty
Initial $6,261 · Current $5,000 Reduced
29 CFR  1910.37(a)(4):  Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:  Loading Dock:  On, or about, June 22, 2023, the exit door labelled "6" would not open.
Recent events (3)
  • — F (O) $5000
  • — C (S) $6261
  • — Z (S) $6261

1910.132 A

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Aug 15, 2023
Abate by
Oct 2, 2023
Penalty
Initial $8,349 · Current $4,500 Reduced
29 CFR  1910.132(a):   Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:  Facility:  On, or about, June 22, 2023 and at time prior to, employees who used Sustainable Earth Wax and Finish Remover were not provided with impervious foot protection to prevent skin contact with ethanolamine, a corrosive chemical that could cause chemical burns and affect the central nervous system when absorbed.
Recent events (3)
  • — F (O) $4500
  • — C (S) $8349
  • — Z (S) $8349

1910.132 D01 I

Other-than-serious Gravity 1 1 instance 4 exposed
Issued
Aug 15, 2023
Abate by
Oct 2, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.132(d)(1)(i):When the employer had assessed the workplace hazard(s) and determined that hazard(s) were present, the employer did not select and/or use the types of personal protective equipment that would protect the affected employee from the hazard:  Facility:  On, or about June 22, 2023, the Personal Protective Equipment Hazard Assessment for Custodial Tasks did not sufficiently address the task of stripping floors.  The product provided for use, Sustainable Earth Wax and Finish Remover, contained Ethanolamine, a chemical that could cause chemical burns and affect the central nervous system.  The hazard assessment only referred employees to the Material Safety Data Sheet for recommended protective equipment instead of assessing the hazards and recommending suitable protective equipment such as eye protection, hand protection and foot protection to prevent contact with the product.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.133 A01

Other-than-serious Gravity 5 2 instances 2 exposed
Issued
Aug 15, 2023
Abate by
Oct 2, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.133(a)(1):  The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  Facility:  On, or about, June 22, 2023, the employer did not ensure that employees who performed custodial tasks involving corrosive chemicals such as, but not limited to, bleach, germicidal cleaners and drain cleaner, wore protective eye equipment.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Other-than-serious Gravity 1 2 instances 2 exposed
Issued
Aug 15, 2023
Abate by
Oct 2, 2023
Penalty
Initial $6,261 · Current $6,000 Reduced
29 CFR  1910.305(g)(1)(iv)(A):  Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  Main Stock Room:  On, or about, June 22, 2023, the following Carrier Cases were energized with flexible cord used in lieu of permanent wiring:  A.	Carrier Case 629 was energized through a black extension cord. B.	Carrier Case 619 was energized through an orange extension cord.
Recent events (3)
  • — F (O) $6000
  • — C (S) $6261
  • — Z (S) $6261

1910.305 G01 IV D

Other-than-serious Gravity 1 4 instances 4 exposed
Issued
Aug 15, 2023
Abate by
Oct 2, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(D):  Flexible cords and cables were used where attached to building surfaces:  Main Stock Room:  On, or about, June 22, 2023, the following Carrier Cases were energized with flexible cord used that was attached to building surfaces:  A.	Carrier Case 623:  Cord was taped to the building column and attached the suspended ceiling grid in two locations. B.	Carrier Case 610:  Cord was tie-wrapped to the conduit for the alarm system. C.	Carrier Case 2002 and 1222:  Cord was attached to the suspended ceiling grid in two locations. D.	Carrier Case 1212:  Cord was attached to the suspended ceiling grid in two locations.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.305 G01 IV E

Other-than-serious Gravity 1 2 instances 2 exposed
Issued
Aug 15, 2023
Abate by
Oct 2, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(E):  Flexible cords and cables were used where concealed behind building walls, ceilings, or floors:   Main Stock Room:  On, or about, June 22, 2023, the following Carrier Cases were energized with flexible cord used that was run over the suspended ceiling:  A.	Carrier Case 619:  Orange extension cord. B.	Carrier Case 610:  Black power cord.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1904.29 B01

Other-than-serious 2 instances 70 exposed
Issued
Aug 15, 2023
Abate by
Oct 2, 2023
Penalty
Initial $0 · Current $0
29 CFR  1904.29(b)(1): A Log of all recordable work-related injuries and illness (OSHA Form 300 or equivalent) was not completed in the detail required by the regulation:  Facility:  On, or about, June 22, 2022, entries with the following case numbers on the 2023 OSHA 300 Log of Work-Related Injuries and Illnesses did not have adequate injury/illness descriptions in Column (F):  A.  Case No. 1846-60. B.  Case No. 2040-86.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.304 B04

Other-than-serious 1 instance 30 exposed
Issued
Aug 15, 2023
Abate by
Oct 2, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.304(b)(4):  Outlet devices had an ampere rating less than the load to be served:  Break Room:  On, or about, June 22, 2023, a Walmart carafe and a Keurig coffee maker were energized through the same 20 ampere wall mounted receptacle.  The combined load of the two appliances was calculated to be 24.49 amperes.