MORENO VALLEY, CA —
OSHA Inspection: U.S. POSTAL SERVICE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of U.S. POSTAL SERVICE in 23800 CACTUS AVENUE, MORENO VALLEY, CA 92553 (NAICS 491110). OSHA activity number 346815749.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. POSTAL SERVICE
- Site address
- 23800 CACTUS AVENUE
- City
- MORENO VALLEY
- State
- CA
- ZIP
- 92553
- Mailing
- 23800 CACTUS AVENUE, MORENO VALLEY, CA 92553
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 491110
- Employees
- 310
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.334 A02 I
- Issued
- Jul 31, 2023
- Penalty
- Initial $9,488 · Current $4,934 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): Custodial Room: On and/or before July 6th, 2023 the employer did not ensure plugged connected electrical equipment was inspected for visual external defects in that, the manufacturers power cord to the HEPA vacuum and the air blower were missing grounding pins. This condition potentially exposed employees to electrical shock and/or fire hazards.
Recent events (2)
- — I (S) $4933.76
- — Z (S) $9488
1910.305 G01 IV A
- Issued
- Jul 31, 2023
- Penalty
- Initial $9,488 · Current $4,934 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure Break Room: On and/or before July 6th, 2023 flexible cords and/or cables were used as a source of permanent power for the true refrigerator. This condition potentially exposed employees to electrical shock and/or fire hazards.
Recent events (2)
- — I (S) $4933.76
- — Z (S) $9488
More inspections at U.S. Postal Service
View U.S. Postal Service's full OSHA safety record →
More inspections in this industry (NAICS 491110)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346815749.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.