Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MOTIS, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of MOTIS, LLC in W210N12975 GATEWAY CROSSING, GERMANTOWN, WI 53022 (NAICS 333992). OSHA activity number 346816077.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Motis, LLC — free Get an email when a new federal OSHA severe-injury report for Motis, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
MOTIS, LLC
Site address
W210N12975 GATEWAY CROSSING
City
GERMANTOWN
State
WI
ZIP
53022
Mailing
W210N12975 GATEWAY CROSSING, GERMANTOWN, WI 53022
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333992
Employees
48
Ownership type
A

2 citations on file for this inspection.

1910.1000 A02

Deleted Serious Gravity 5 3 instances 3 exposed
Issued
Dec 21, 2023
Abate by
Feb 9, 2024
Penalty
Initial $8,539 · Current $0 Reduced
29 CFR  1910.1000(a)(2): An employee's exposure to any substance in Table Z-1, the exposure limit of which is not preceded by a "C", shall not exceed the 8-hour Time Weighted Average given for that substance any 8-hour work shift of a 40-hour work week.  (a) On or about August 9, 2023, an employee engaged in welding operations, welding station #19 was exposed to dust that exceeded the permissible exposure limit (PEL) while performing routine fabrication of manufactured products. The employee was exposed to an 8-hour time weighted average (TWA) of 18.35 mg/m3 of dust, which was approximately 1.22 times the Permissible Exposure Limit (PEL) of  15mg/m3 for the total dust fraction of particulate not otherwise regulated (PNOR) during the 262 minute sampling period sampled. Zero exposure assumed for the unsampled period of 218 minutes.  (b) On or about August 9, 2023, an employee engaged in welding operations, welding station #4 was exposed to dust that exceeded the permissible exposure limit (PEL) while performing routine fabrication of manufactured products. The employee was exposed to an 8-hour time weighted average (TWA) of 18.71 mg/m3 of dust, which was approximately 1.24 times the Permissible Exposure Limit (PEL) of 15mg/m3 for the total dust fraction of particulate not otherwise regulated (PNOR) during the 405 minute sampling period sampled. Zero exposure assumed for the unsampled period of 75 minutes.  (c) On or about August 9, 2023, an employee engaged in welding operations, welding station #17 was exposed to dust that exceeded the permissible exposure limit (PEL) while performing routine fabrication of manufactured products. The employee was exposed to an 8-hour time weighted average (TWA) of 23.51 mg/m3 of dust, which was approximately 1.56 times the Permissible Exposure Limit (PEL) of 15mg/m3 for the total dust fraction of particulate not otherwise regulated (PNOR) during the 395 minute sampling period sampled. Zero exposure assumed for the unsampled period of 85 minutes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8539

1910.1000 E

Other-than-serious Gravity 5 3 instances 3 exposed
Issued
Dec 21, 2023
Abate by
May 6, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.1000(e): To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.  At the facility located at, W210N12975 Gateway Crossing Germantown, Wisconsin;  the employer did not determine and implement feasible administrative or engineering controls to achieve compliance with paragraph (a) of this section:  (a) On or about August 9, 2023, the employer did not implement proper engineering and administrative controls to reduce employee exposures below the permissible exposure limit (PEL) for the total dust fraction of particulate not otherwise regulated (PNOR) for employees performing routine production welding. Three employees engaged in welding operations had exposures that exceeded the PEL for PNOR on this sampling date (see citation 1 item 1a instances a. through c. for exposure information.)
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346816077.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.