Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HD EXCAVATIONS & UTILITIES LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HD EXCAVATIONS & UTILITIES LLC in 111 BLUFFS CT., CANTON, GA 30114 (NAICS 237110). OSHA activity number 346820202.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch HD Excavations & Utilities LLC — free Get an email when a new federal OSHA severe-injury report for HD Excavations & Utilities LLC is published. One employer, no account, unsubscribe in one click.
Site address
111 BLUFFS CT.
City
CANTON
State
GA
ZIP
30114
Mailing
516 COLE CREEK ROAD, DALLAS, GA 30157
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.651 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 2, 2023
Penalty
Initial $3,349 · Current $2,009 Reduced
29 CFR  1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  a) Excavation located at 111 Bluffs Ct., Canton, GA 30114: On or about 07/10/2023, the employer exposed employees to cave-in/engulfment hazards while working inside a trench which measured 6-feet, 3-inches deep by 4-feet, 8-inches wide by 15-feet, 7-inches long, in that a safe means of egress was not provided to employees installing 8-Inch ductile pipe.
Recent events (2)
  • — I (S) $2009.4
  • — Z (S) $3349

1926.652 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 2, 2023
Penalty
Initial $3,349 · Current $2,009 Reduced
29 CFR  1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).  a) Excavation located at 111 Bluffs Ct., Canton, GA 30114: On or about 07/10/2023, the employer exposed an employee to cave-in/engulfment hazards while working inside an excavation which measured 6-feet, 3-inches deep by 4-feet, 8-inches wide by 15-feet, 7-inches long, in that an adequate cave-in protection system was not provided to employees engaged in storm drain pipe installations.
Recent events (2)
  • — I (S) $2009.4
  • — Z (S) $3349

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346820202.