Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GREENHECK FAN CORPORATION - FACILITY 2

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of GREENHECK FAN CORPORATION - FACILITY 2 in 1111 GREENHECK DRIVE, SCHOFIELD, WI 54476 (NAICS 333413). OSHA activity number 346826183.

Watch Greenheck FAN Corporation - Facility 2 — free Get an email when a new federal OSHA severe-injury report for Greenheck FAN Corporation - Facility 2 is published. One employer, no account, unsubscribe in one click.
Site address
1111 GREENHECK DRIVE
City
SCHOFIELD
State
WI
ZIP
54476
Mailing
405 ALDERSON STREET BLDG 17, SCHOFIELD, WI 54476
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333413
Employees
280
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $15625.00 · Current $0.00 Reduced
29 CFR  1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the requirements of section(c)(4)(ii)(A)-(c)(4)(ii)(D) of this standard.  On or about July 10, 2023, with regard to an establishment located at 1111 Greenheck Drive, Schofield, WI 54476, the employer did not ensure that the hazardous energy controls procedures for Integrated Blanking System #1, including the Operator Safety Control Zones, provided clear and specific guidance for effective means and methods of hazardous energy control during service and maintenance tasks. Operators utilizing the Operator Safety Control Zone portion of the hazardous energy control plan could still access hazard areas when the methods described in the plan allowed for options that did not control potentially hazardous energy.
Recent events (3)
  • — F (S) $0
  • — C (S) $15625
  • — Z (S) $15625

1910.147 C06 I

Serious Gravity 10 1 instance 280 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  On or about July 10, 2023, with regard to an establishment located at 1111 Greenheck Drive, Schofield, WI 54476, the employer did not ensure that a periodic inspection of all energy control procedures had been completed within the previous twelve months to ensure that the procedure was determined to be effective, and the requirements of the standard were being followed.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 10 1 instance 10 exposed
Issued
Penalty
Initial $0.00 · Current $15625.00
29 CFR  1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  On or about July 10, 2023, with regard to an establishment located at 1111 Greenheck Drive, Schofield, WI 54476, the employer did not ensure that all employees engaged in service and maintenance tasks associated with the Integrated Blanking Systems were trained in the methods and means necessary for energy isolation and control when entering hazardous areas.
Recent events (3)
  • — F (S) $15625
  • — C (S) $0
  • — Z (S) $0

5(a)(1)

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $15625.00 · Current $15625.00
OSH ACT of 1970 Section (5)(a)(1)  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees 29 CFR  1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  On or about July 10, 2023, an employee, engaged in unjamming and alignment activities within the STOPA safety zone of Integrated Blanking System 1, was exposed to unexpected hazardous energy in the form of a moving cart. The alternative safety measures described on the Employer?s Operator Safety Control Zone Map for the STOPA safety zone did not provide enough clear and specific guidance for effective means for controlling that hazardous energy.?
Recent events (3)
  • — F (S) $15625
  • — C (S) $15625
  • — Z (S) $15625

View GREENHECK FAN CORPORATION - FACILITY 2's full OSHA safety record →