Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PEDRO MACEDA DE LOS SANTOS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PEDRO MACEDA DE LOS SANTOS in 880 NORTHSTAR FLATS DRIVE (BUILDING 3), SUNBURY, OH 43074 (NAICS 238170). OSHA activity number 346831407.

Watch Pedro Maceda DE LOS Santos — free Get an email when a new federal OSHA severe-injury report for Pedro Maceda DE LOS Santos is published. One employer, no account, unsubscribe in one click.
Site address
880 NORTHSTAR FLATS DRIVE (BUILDING 3)
City
SUNBURY
State
OH
ZIP
43074
Mailing
5690 IRONWOOD CT. - APT. A, COLUMBUS, OH 43229
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.451 G03 IV

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4688.00 · Current $4688.00
29 CFR 1926.451(g)(3)(iv): Vertical lifelines, independent support lines, and suspension ropes shall not be attached to each other, nor shall they be attached to or use the same point of anchorage, nor shall they be attached to the same point on the scaffold or personal fall arrest system.  a. Located at the job site at 880 Northstar Flats Drive (Building 3), Sunbury, Ohio: On or about July 12, 2023, and at times prior, two employees worked from a pump jack scaffold installing sofit and fascia utilizing full-body harnesses with lanyards and vertical lifelines that were connected to the same Guardian temper anchor. As a result, employees were exposed to fall hazards of up to approximately 25 feet.
Recent events (2)
  • — I (S) $4688
  • — Z (S) $4688

1926.451 B03

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3349.00 · Current $0.00 Reduced
29 CFR 1926.451(b)(3): Except as provided in paragraphs (b)(3)(i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling.  a. Located at the job site at 880 Northstar Flats Drive (Building 3), Sunbury, Ohio: On or about July 12, 2023, and at times prior, two employees worked from a pump jack scaffold installing sofit and fascia which had its front edge approximately 18 inches from the face of the building.  Employees were thereby exposed to fall hazards of approximately 25 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3349

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4688.00 · Current $0.00 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.  a. Located at the job site at 880 Northstar Flats Drive (Building 3), Sunbury, Ohio: On or about July 12, 2023, and at times prior, two employees worked from a pump jack scaffold at approximately 25 feet from ground level, installing sofit and fascia to the exterior of a new-build three-story apartment building without utilizing fall protection measures. Employees were thereby exposed to fall hazards of approximately 25 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4688

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346831407.