MIAMI BEACH, FL —
OSHA Inspection: TULE GROUP INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of TULE GROUP INC. in 315 NORTH SHORE DRIVE, MIAMI BEACH, FL 33141 (NAICS 236115). OSHA activity number 346834583.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TULE GROUP INC.
- Site address
- 315 NORTH SHORE DRIVE
- City
- MIAMI BEACH
- State
- FL
- ZIP
- 33141
- Mailing
- 11931 SW 208 TERRACE MIAMI, FL 33177, MIAMI, FL 33177
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 10
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.703 A01
- Issued
- Jan 8, 2024
- Penalty
- Initial $4,018 · Current $4,018
General-duty citation text
29 CFR 1926.703(a)(1): Formwork was not designed, fabricated, erected, supported, braced, and maintained so that it would be capable of supporting without failure all vertical and lateral loads that could reasonably be anticipated to be applied to the form: On or about July 12, 2023 and at times prior, at 315 North Shore Drive, Miami Beach, FL, 33141, employees were exposed to a struck-by hazard while working in an area where shoring poles were replaced by shorter poles on top of cracked concrete blocks.
Recent events (1)
- — Z (S) $4018
1926.703 B06
- Issued
- Jan 8, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.703(b)(6): Base plates, shore heads, extension devices, and adjustment screws were not in firm contact, and secured, when necessary, with the foundation and the form: On or about July 12, 2023, at the job site located at 315 North Shore Drive, Miami Beach, FL, 33141, employees were exposed to a struck-by hazard while working in an area where shoring poles were replaced by shorter poles on top of cracked concrete blocks, therefore did not make firm contact with the foundation.