Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KUGLER OIL COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KUGLER OIL COMPANY in 71748 RAILROAD AVENUE, CULBERTSON, NE 69024 (NAICS 325311). OSHA activity number 346841844.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kugler OIL Company — free Get an email when a new federal OSHA severe-injury report for Kugler OIL Company is published. One employer, no account, unsubscribe in one click.
Establishment
KUGLER OIL COMPANY
Site address
71748 RAILROAD AVENUE
City
CULBERTSON
State
NE
ZIP
69024
Mailing
P.O. BOX 1748, MCCOOK, NE 69001
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325311
Employees
101
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 21, 2023
Abate by
Feb 9, 2024
Penalty
Initial $14,063 · Current $9,844 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees.  Employees were exposed to a fire and explosion hazard while manually igniting a propane torch to heat the sulfur burner vessel. This was documented to occur on or about July 19, 2023.  A propane torch was manually lit by an employee and placed in the vessel port opening, the torch failed to maintain a flame and allowed propane gas to accumulate near the port opening creating a fire and explosion hazard.  Employees were exposed to the fire and explosion hazards while attempting to reignite the flame.   AMONG OTHER METHODS, FEASIBLE AND ACCEPTABLE ABATEMENT METHODS INCLUDE BUT ARE NOT LIMITED TO:   1. Develop, implement, and communicate to employees written work rules that address safe start-up and restart procedures and operating and troubleshooting instructions for the Ammonium Thiosulfate (ATS) plant in accordance with manufacturer recommendations.   2. Remove the bypass valve and re-incorporate the use of an automated system to pre-heat the ATS plant per the manufacturer as outlined in North American Mfg Co. Bulletin 46.96 2-79 for the Gas-Compressed Air Torches operator manual.
Recent events (2)
  • — I (S) $9844
  • — Z (S) $14063

1910.132 A

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 21, 2023
Penalty
Initial $14,063 · Current $9,844 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:  Employees engaged in Ammonium Thio Sulfide (ATS) production activities located at 71748 Railroad Drive, Culbertson, Nebraska 69024, were exposed to fire and explosions hazards in that the employer failed to provide employees with fire retardant clothing and face shields to wear while pre-heating the Sulphur burner.
Recent events (2)
  • — I (S) $9844
  • — Z (S) $14063

1910.147 C04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 21, 2023
Abate by
Jan 19, 2024
Penalty
Initial $10,046 · Current $7,032 Reduced
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  Employees engaged in maintenance operations at 71748 Railroad Drive, Culbertson, Nebraska 69024, were exposed to electrical hazardous energy release in that the employer failed to develop and implement written lockout tagout procedures for the gas fan in the ATS plant.
Recent events (2)
  • — I (S) $7032
  • — Z (S) $10046

1910.147 F03 II D

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 21, 2023
Abate by
Jan 19, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(3)(ii)(D):Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment:  Employees engaged in maintenance operations at 71748 Railroad Drive, Culbertson, Nebraska 69024, were exposed to electrical hazardous energy releases in that the employer failed to ensure that each authorized person affixed their personal lockout device before performing maintenance on the gas fan in the ATS plant.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 III D

Other-than-serious Gravity 1 1 instance 3 exposed
Issued
Dec 21, 2023
Penalty
Initial $6,026 · Current $4,218 Reduced
29 CFR 1910.305(b)(1)(iii)(D):The raceway is sealed or plugged at the outer end using approved means so as to prevent access to the enclosure through the raceway;  Employees engaged in Ammonium Thio Sulfide (ATS) production activities located at 71748 Railroad Drive, Culbertson, Nebraska 69024, were exposed to electrical hazards in that the employer failed to protect employees engaged in using the igniter torch during the pre-heat startup for the ATS plant. The raceway attached to the igniter torch was not sealed or plugged on the outer end exposing live electrical wiring.
Recent events (2)
  • — I (O) $4218
  • — Z (S) $6026

1910.305 B01 III F

Other-than-serious Gravity 1 1 instance 3 exposed
Issued
Dec 21, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(iii)(F):29CFR1910.305(b)(1)(iii)(F): The raceway was not fastened at its outer end and other places as necessary:  Employees engaged in Ammonium Thio Sulfide (ATS) production activities located at 71748 Railroad Drive, Culbertson, Nebraska 69024, were exposed to electrical hazards in that the employer failed to protect employees engaged in using the igniter torch during the pre-heat startup for the ATS plant. The raceway attached to the igniter torch was not fastened at its outer end or other places as necessary.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View Kugler OIL Company's full OSHA safety record →