ONALASKA, WI —
OSHA Inspection: DYNAMIC LIFECYCLE INNOVATIONS, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of DYNAMIC LIFECYCLE INNOVATIONS, INC. in N5549 COUNTY ROAD Z, ONALASKA, WI 54650 (NAICS 562920). OSHA activity number 346848385.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DYNAMIC LIFECYCLE INNOVATIONS, INC.
- Site address
- N5549 COUNTY ROAD Z
- City
- ONALASKA
- State
- WI
- ZIP
- 54650
- Mailing
- N5549 COUNTY ROAD Z, ONALASKA, WI 54650
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562920
- Employees
- 100
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.134 I01 II C
- Issued
- Dec 12, 2023
- Abate by
- Jan 4, 2024
- Penalty
- Initial $5,692 · Current $0 Reduced
0560
General-duty citation text
29 CFR 1910.134(i)(1)(ii)(C): Breathing air contained carbon monoxide at greater than 10 parts per million: On July 26, 2023, in the glass room in the CRT area of the workplace, located at N5549 County Road Z, Onalaska, WI, employees manually breaking glass of CRT tubes were exposed to up to 14 ppm of carbon monoxide in the breathing air of their supplied air respirators.
Recent events (2)
- — I (S) $0
- — Z (S) $5692
1910.134 I07
- Issued
- Dec 12, 2023
- Abate by
- Jan 4, 2024
- Penalty
- Initial $0 · Current $4,269
0560
General-duty citation text
29 CFR 1910.134(i)(7): Oil-lubricated compressor(s) equipped with only high-temperature alarm(s) were used to supply breathing air and the air supply was not monitored at intervals sufficient to prevent carbon monoxide in the breathing air from exceeding 10 ppm: On or about July 26, 2023, an Atlas Copco G11-FF air compressor, equipped with only a high-temperature alarm, supplied breathing air to glass-room employees' supplied air respirators that was not monitored at intervals sufficient to prevent carbon monoxide in the breathing air from exceeding 10 ppm.
Recent events (2)
- — I (S) $4269
- — Z (S) $0
1910.1000 D01 I
- Issued
- Dec 12, 2023
- Abate by
- Jan 11, 2024
- Penalty
- Initial $9,488 · Current $7,116 Reduced
1591C141
General-duty citation text
29 CFR 1910.1000(d)(1)(i): When determined by the computational formula specified in 29 CFR 1910.1000(d)(2)(i), employees were exposed to concentrations of more than one substance for which 8-hour time weighted averages are listed in Subparts Z of 29 CFR part 1910 in excess of the permissible exposure for the mixture: On July 26, 2023, the employer did not ensure that employee exposure to concentrations of more than one substance did not exceed the permissible exposure limit for the mixture of heavy metals to include inorganic Lead and Cadmium. This mixture has additive toxic effects on the kidneys. An employee dismantling Cathode Ray Tubes in the glass room in the CRT area was exposed to inorganic Lead at an 8-hour time weighted average (TWA) of 0.0523 milligrams per cubic meter (mg/m3) of air, approximately 1.046 times the Permissible Exposure Limit (PEL) of 0.05 mg/m3. The employee was also exposed to Cadmium at an 8-hour TWA of .0021 mg/m3 of air, approximately 0.42 times the PEL of 0.005 mg/m3. The exposure to the mixture was approximately 1.46 times the permissible 8-hour TWA concentration for the mixture. Sampling was performed for 416 minutes, with zero exposure assumed for the 64 minutes not sampled.
Recent events (2)
- — I (S) $7116
- — Z (S) $9488
1910.1000 E
- Issued
- Dec 12, 2023
- Abate by
- Jan 11, 2024
- Penalty
- Initial $0 · Current $0
1591C141
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): On July 26, 2023, the employer did not ensure that employee exposure to concentrations of more than one substance did not exceed the permissible exposure limit for the mixture of heavy metals to include inorganic Lead and Cadmium. This mixture has additive toxic effects on the kidneys. An employee dismantling Cathode Ray Tubes in the glass room in the CRT area was exposed to inorganic Lead at an 8-hour time weighted average (TWA) of 0.0523 milligrams per cubic meter (mg/m3) of air, approximately 1.046 times the Permissible Exposure Limit (PEL) of 0.05 mg/m3. The employee was also exposed to Cadmium at an 8-hour TWA of .0021 mg/m3 of air, approximately 0.42 times the PEL of 0.005 mg/m3. The exposure to the mixture was approximately 1.46 times the permissible 8-hour TWA concentration for the mixture. Sampling was performed for 416 minutes, with zero exposure assumed for the 64 minutes not sampled.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1025 D06 II
- Issued
- Dec 12, 2023
- Abate by
- Jan 4, 2024
- Penalty
- Initial $9,488 · Current $7,116 Reduced
1591
General-duty citation text
29 CFR 1910.1025(d)(6)(ii): Where the initial determination or subsequent monitoring revealed employee exposure to lead to be at or above the action level but below the permissible exposure limit; monitoring was not repeated at least every six months: On July 26, 2023, in the glass room in the CRT area of the workplace located at N5549 County Road Z, Onalaska, WI, employees manually breaking the leaded glass of Cathode Ray Tubes and exposed to lead above the action level had not had their personal exposure to lead monitored at least every six months.
Recent events (2)
- — I (S) $7116
- — Z (S) $9488
1910.1025 D07
- Issued
- Dec 12, 2023
- Abate by
- Jan 4, 2024
- Penalty
- Initial $0 · Current $0
1591
General-duty citation text
29 CFR 1910.1025(d)(7): Additional exposure monitoring was not conducted when there was a change in production, process, control or personnel, or any other reason to suspect a change that may have resulted in new or additional exposure to lead: On July 26, 2023, in the glass room in the CRT area of the workplace located at N5549 County Road Z, Onalaska, WI, employees manually breaking the leaded glass of Cathode Ray Tubes had not had their personal exposure to lead monitored after a September 2022 change in the design and function of the glass room that may have resulted in new or additional exposure to lead.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1025 H02 II
- Issued
- Dec 12, 2023
- Abate by
- Jul 1, 2024
- Penalty
- Initial $5,692 · Current $4,269 Reduced
1591
General-duty citation text
29 CFR 1910.1025(h)(2)(ii): Shoveling, sweeping or brushing methods were used to remove lead accumulations where vacuuming or other equally effective methods were available and feasible: On or about July 20, 2023, in the CRT area located at N5549 County Road Z, Onalaska, WI. Recycling Production 1 employees shoveled and swept lead accumulations in the glass room and the dropout of the funnel glass pulverisor.
Recent events (2)
- — I (O) $4269
- — Z (S) $5692
More inspections at Dynamic Lifecycle Innovations, INC.
View Dynamic Lifecycle Innovations, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 562920)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346848385.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.