DAYTON, OH —
OSHA Inspection: DAYTON WINDUSTRIAL
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of DAYTON WINDUSTRIAL in 117 EAST HELENA STREET, DAYTON, OH 45404 (NAICS 332996). OSHA activity number 346852577.
Where did this inspection happen?
- Establishment
- DAYTON WINDUSTRIAL
- Site address
- 117 EAST HELENA STREET
- City
- DAYTON
- State
- OH
- ZIP
- 45404
- Mailing
- 137 EAST HELENA STREET, DAYTON, OH 45404
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332996
- Employees
- 13
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.132 D01 I
- Issued
- Abate by
- Penalty
- Initial $3036.00 · Current $2125.00 Reduced
General-duty citation text
29 CFR 1910.132(d)(1)(i): Hazard assessment and equipment selection. The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall: Select, and have each affected employee use, the types of PPE that will protect the affected employee from the hazards identified in the hazard assessment; a) On or about July 27, 2023, the employer did not ensure that welders wore protective equipment, such as but not limited to fire resistant welding jackets, to protect their arms and torso from sparks.
Recent events (2)
- — I (S) $2125.2
- — Z (S) $3036
1910.252 B03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.252(b)(3):Protective clothing - General requirements. Employees exposed to the hazards created by welding, cutting, or brazing operations shall be protected by personal protective equipment in accordance with the requirements of 1910.132. Appropriate protective clothing required for any welding operation will vary with the size, nature and location of the work to be performed. a) On or about July 27, 2023, the employer did not ensure that welders wore protective equipment, such as but not limited to weld jackets, to protect their arms and torso from sparks.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 D02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(d)(2):The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment. a) On or about July 24, 2023, the employer did not certify in writing that they had completed a workplace hazard assessment to determine what personal protective equipment would protect employees from the hazards identified in the workplace for job tasks including but not limited to welding and threading of production pipe.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L06
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(6):Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation. a) On or about July 24, 2023, the employer failed to certify that each employee had been trained and evaluated prior to operating a forklift in that employees were operating a Toyota Forklift (Model: 426FGCCU20 Serial: 8221) and a Nissan Forklift ( Model: MCPL02A25LV Serial: CPL02-9P2835) without certification of training.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at DAYTON WINDUSTRIAL
VANDALIA, OH—2011-05-25 00:00:00
DAYTON WINDUSTRIAL
View DAYTON WINDUSTRIAL's full OSHA safety record →
More inspections in this industry (NAICS 332996)
ELK POINT, SD—2026-07-07
NEXT MECHANICAL
HARRISON, OH—2026-06-25
ENERFAB MODULAR SHOP
PENNSAUKEN, NJ—2026-06-15
PIONEER PIPE CONTRACTORS, INC.
MEMPHIS, TN—2026-05-28
ISLAND INDUSTRIES, INC.
LEBANON, TN—2026-05-27
FERGUSON ENTERPRISES, LLC
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346852577.