Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VAN ERT ELECTRIC COMPANY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VAN ERT ELECTRIC COMPANY, INC. in 2006 NEWBERRY STREET, APPLETON, WI 54915 (NAICS 238210). OSHA activity number 346855547.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch VAN ERT Electric Company, INC. — free Get an email when a new federal OSHA severe-injury report for VAN ERT Electric Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2006 NEWBERRY STREET
City
APPLETON
State
WI
ZIP
54915
Mailing
2000 PROGRESS WAY, KAUKAUNA, WI 54130
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
700
Ownership type
A

4 citations on file for this inspection.

1926.961 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 9, 2024
Abate by
Feb 7, 2024
Penalty
Initial $15,625 · Current $15,625
29 CFR  1926.961(c)(2):Open disconnecting means. The employer shall ensure that all switches, disconnectors, jumpers, taps, and other means through which known sources of electric energy may be supplied to the particular lines and equipment to be deenergized are open. The employer shall render such means inoperable, unless its design does not so permit, and then ensure that such means are tagged to indicate that employees are at work.  On or about July 14, 2023, at the jobsite located at 2006 Newberry Street Appleton, Wisconsin; the employer did not ensure all sources of electrical energy that may be supplied to the lines and equipment of the Power Distribution Center (PDC) were open, exposing employees to electrical hazards while sealing the conduits on the load side of the PDC prior to energization.
Recent events (2)
  • — I (S) $15625
  • — Z (S) $15625

1926.961 C06

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 9, 2024
Abate by
Feb 7, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.961(c)(6): Test for energized condition. After the applicable requirements in paragraphs (c)(1) through (c)(5) of this section have been followed and the system operator gives a clearance to the employee in charge, the employer shall ensure that the lines and equipment are deenergized by testing the lines and equipment to be worked with a device designed to detect voltage.   On or about July 14, 2023, at the jobsite located at 2006 Newberry Street Appleton, Wisconsin; the employer did not ensure that an employee working on line side of a Power Distribution Center verified the lines and equipment were deenergized before installing the insulating boots on the equipment.  The PDC was operating at approximately 4,160 VAC
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.962 B

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jan 9, 2024
Abate by
Feb 7, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.962(b):General. For any employee to work transmission and distribution lines or equipment as deenergized, the employer shall ensure that the lines or equipment are deenergized under the provisions of � 1926.961 and shall ensure proper grounding of the lines or equipment as specified in paragraphs (c) through (h) of this section. However, if the employer can demonstrate that installation of a ground is impracticable or that the conditions resulting from the installation of a ground would present greater hazards to employees than working without grounds, the lines and equipment may be treated as deenergized provided that the employer establishes that all of the following conditions apply:  On or about July 14, 2023, at the jobsite located at 2006 Newberry Street Appleton, Wisconsin; the employer did not ensure all equipment was deenergized and grounds installed before allowing employees to work on the equipment downstream.  Employees were exposed to electrical hazards while sealing the conduits on the line side of the PDC prior to energization.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.966 G02

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 9, 2024
Abate by
Feb 7, 2024
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR  1926.966(g)(2): Job briefing. The job briefing required by � 1926.952 shall cover information on special system conditions affecting employee safety, including the location of energized equipment in or adjacent to the work area and the limits of any deenergized work area.   On or about July 14, 2023, at the jobsite located at 2006 Newberry Street Appleton, Wisconsin; the employer failed to ensure that the job briefing required by 1926.952 covered information on special system conditions affecting employee safety, including the location of energized busbars inside the power distribution center, exposing employees to an electric shock hazard.  Bay doors on Number 5, and Number 12, had energized bus bars on the line side of the Power Distribution Center.
Recent events (2)
  • — I (S) $0
  • — Z (S) $15625

View VAN ERT Electric Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346855547.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.