RIVER FALLS, WI —
OSHA Inspection: ADVANCED SOLUTIONS BUILDERS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ADVANCED SOLUTIONS BUILDERS LLC in 1063 EAST CASCADE AVENUE, RIVER FALLS, WI 54022 (NAICS 238160). OSHA activity number 346862915.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED SOLUTIONS BUILDERS LLC
- Site address
- 1063 EAST CASCADE AVENUE
- City
- RIVER FALLS
- State
- WI
- ZIP
- 54022
- Mailing
- 400 SOUTH 4TH STREET, SUITE 410, UNIT 45070, MINNEAPOLIS, MN 55415
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Sep 1, 2023
- Abate by
- Sep 18, 2023
- Penalty
- Initial $3,984 · Current $1,992 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Residential multiplex roof structure, south end; Employee(s) engaged in roofing construction activities were not protected from falls while working at approximate heights ranging between 17-feet, 3-inches to 23-feet, 6-inches above ground-level.
Recent events (2)
- — I (S) $1992
- — Z (S) $3984
1926.1053 B01
- Issued
- Sep 1, 2023
- Penalty
- Initial $2,846 · Current $1,423 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) Residential multiplex, southwest side; The side rails of a 24-foot Keller brand model 5124 fiberglass extension ladder, used by employee(s) to access and egress the roof, did not extend at least 3-feet above the landing surface.