MADISON, ME —
OSHA Inspection: BOB'S CASH FUEL INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BOB'S CASH FUEL INC. in 424 MAIN STREET, MADISON, ME 04950 (NAICS 454310). OSHA activity number 346876634.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOB'S CASH FUEL INC.
- Site address
- 424 MAIN STREET
- City
- MADISON
- State
- ME
- ZIP
- 04950
- Mailing
- P.O. BOX 70, MADISON, ME 04950
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 454310
- Employees
- 39
- Ownership type
- A
Citations
15 citations on file for this inspection.
1910.107 B01
- Issued
- Sep 13, 2023
- Penalty
- Initial $7,969 · Current $7,172 Reduced
General-duty citation text
29 CFR 1910.107(b)(1): The spray booth�was not�substantially constructed�of steel,�that was securely and�rigidly supported,�or of�concrete or�masonry: Pizza Hut Spray Booth - The spray booth�was not�constructed of a steel, concrete, masonry, or other non combustible material.
Recent events (2)
- — I (O) $7172.1
- — Z (S) $7969
1910.107 C04
- Issued
- Sep 13, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(c)(4): Electrical wiring and equipment did not conform to the provisions of this paragraph and were not otherwise in accordance with subpart S of this part: Pizza Hut Spray Booth - The spray booth lighting and outlets were not intrinsically safe and did not meet the requirements of 29 CFR 1910.307(c).
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.107 D05
- Issued
- Sep 13, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(d)(5): Electric motor(s) driving exhaust fan(s) for spray booth(s) were located inside the booth(s) and did not meet the requirements of subpart S of this part: Pizza Hut Spray Booth - A Canarm XFS12 exhaust fan that was installed in the spray booth, where flammable paints and solvents were sprayed, did not meet the requirements in subpart S for hazardous locations.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.134 C
- Issued
- Sep 13, 2023
- Penalty
- Initial $5,645 · Current $5,081 Reduced
General-duty citation text
29 CFR 1910.134(c): The employer did not develop, and implement, a written respiratory protection program with required worksite-specific procedures, and elements, for required respirator use: Bobs Cash Fuel Facility - Employer did not develop and implement a written respiratory protection program for employee(s) required to wear respirators.
Recent events (2)
- — I (O) $5080.5
- — Z (S) $5645
1910.134 E01
- Issued
- Sep 13, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was required to use a respirator in the workplace: Bobs Cash Fuel Facility - Employer did not provide a medical evaluation for employee(s) required to wear a respirator, during the refurbishing process of propane tanks.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.134 F01
- Issued
- Sep 13, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): Bobs Cash Fuel Facility - Employer did not provide a fit test for employee(s) required to wear a respirator, during the refurbishing of propane tanks.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.134 G01 I A
- Issued
- Sep 13, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face: Pizza Hut - An employee with facial hair wore a respirator with a tight-fitting facepiece, which came between the sealing surface of the respirator and the face.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.134 K
- Issued
- Sep 13, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k): The employer did not provide initial, and annual, comprehensive and understandable respirator training to employees who were required to use a respirator in the workplace: Bobs Cash Fuel Facility - Employee(s) who were assigned to refurbished propane tanks, and required to wear respiratory protection, did not receive respiratory protection training in accordance with 1910.134(k)(1).
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.178 L02 II
- Issued
- Sep 13, 2023
- Penalty
- Initial $6,641 · Current $5,977 Reduced
General-duty citation text
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed training consisting of a combination of formal instruction, practical training , and evaluation of the operator's performance in the workplace: Bobs Cash Fuel Facility - The employer did not ensure that each operator had successfully completed training that included an evaluation of the operator's performance.
Recent events (2)
- — I (O) $5976.9
- — Z (S) $6641
1910.178 Q07
- Issued
- Sep 13, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: Bobs Cash Fuel Facility - Powered industrial truck(s) were not examined prior to being placed into service.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.110 B18
- Issued
- Sep 13, 2023
- Penalty
- Initial $5,645 · Current $5,081 Reduced
General-duty citation text
29 CFR 1910.110(b)(18): Fixed electrical equipment and wiring, installed within classified areas, specified in Table H-28, did not comply with Table H-28 or in accordance with subpart S of this part: Pizza Hut - Approximately (103) 20-pound propane tanks were stored in the vicinity of outlets, lighting fixtures, tools, and wiring that was not intrinsically safe and approved for Class 1 Division 2, as specified in Subpart S.
Recent events (2)
- — I (O) $5080.5
- — Z (S) $5645
1904.41 A02
- Issued
- Sep 13, 2023
- Penalty
- Initial $1,129 · Current $0 Reduced
General-duty citation text
29 CFR 1904.41(a)(2): The employer did not submit an annual electronic submission of OSHA Form 300A, Summary of Work-Related Injuries and Illnesses, who had 20 or more employees but fewer than 250 employees, and was listed as a designated industry in appendix A to subpart E of this part: Bobs Cash Fuel Facility - On or about March 2, 2023, the employer failed to electronically submit information from their OSHA Form 300A, or equivalent.
Recent events (2)
- — I (O) $0
- — Z (O) $1129
1910.25 B01
- Issued
- Sep 13, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.25(b)(1): The employer did not ensure that handrails, stair rail systems, and/or guardrail systems were provided in accordance with � 1910.28: Pizza Hut - The employer did not ensure that handrails, stair rail systems, and/or guardrail systems were provided on both sides of the access stairs for the pizza hut, which contained (5) risers and (4) treads.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.107 G07
- Issued
- Sep 13, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(7): No smoking sign(s) in large letters, on contrasting background color, were not conspicuously posted at all spraying areas: Pizza Hut - A "no smoking" sign was not posted in the spray area.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.132 D02
- Issued
- Sep 13, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: Pizza Hut , Propane Tank Refurbishing Area - The employer did not verify, through a written certification, that a required workplace hazard assessment had been performed prior to having employees work in an environment that required the use of personal protective equipment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 454310)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346876634.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.