OSHA Inspection: DEE PACKAGING SOLUTIONS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DEE PACKAGING SOLUTIONS, INC. in 1204 EAST 12TH STREET BLDG. 3 &4, WILMINGTON, DE 19802 (NAICS 424990). OSHA activity number 346877897.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch DEE Packaging Solutions, INC. — free Get an email when a new federal OSHA severe-injury report for DEE Packaging Solutions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1204 EAST 12TH STREET BLDG. 3 &4
City
WILMINGTON
State
DE
ZIP
19802
Mailing
100 BROOMALL STREET, CHESTER, PA 19013
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Last modified
Data loaded
NAICS code
424990
Employees
6
Ownership type
A

16 citations on file for this inspection.

1910.22 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 29, 2024
Abate by
Feb 15, 2024
Penalty
Initial $9,680 · Current $9,680
29 CFR 1910.22(a)(3): The employer did not ensure that walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice.   a) 1204 E. 12th St., Wilmington, DE 19802 (Building #3): On or about August 3, 2023, the walking/working surface near the rear overhead doors (Northside) were not maintained free of hazards such as loose boards and gaps greater the 2 inches exposing employees to trip and fall hazards.
Recent events (1)
  • — Z (S) $9680

1910.36 B01

Serious Gravity 10 3 instances 2 exposed
Issued
Jan 29, 2024
Abate by
Feb 23, 2024
Penalty
Initial $11,292 · Current $11,292
29 CFR 1910.36(b)(1): Two exit routes. At least two exit routes were not available in the workplace to permit prompt evacuation of employees and other building occupants during an emergency, except as allowed in paragraph (b)(3) of this section. The exit routes must be located as far away as practical from each other so that if one exit route is blocked by fire or smoke, employees can evacuate using the second exit route:   a) 1204 E. 12th St., Wilmington, DE 19802 (Building #3/ North side Door): On or about August 3, 2023, employees working in the warehouse were exposed to egress delays due to exit doors that were rusted shut, locked, or blocked resulting in the exit doors not being operational. This hazard would have resulted in exposing employees to potential entrapment due to smoke or fire during an emergency evacuation.  b) 1204 E. 12th St., Wilmington, DE 19802 (Building #3/ Southside Door): On or about August 3, 2023, employees working in the warehouse were exposed to egress delays due to exit doors that were missing door hardware and blocked resulting in the exit doors not being operational. This hazard would have resulted in exposing employees to potential entrapment due to smoke or fire during an emergency evacuation.  c) 1204 E. 12th St., Wilmington, DE 19802 (Eastside Door/Building #4): On or about August 3, 2023, employees working in the warehouse were exposed to egress delays due to exit doors that were locked using a hasp resulting in the exit doors not being operational. This hazard would have resulted in exposing employees to potential entrapment due to smoke or fire during an emergency evacuation.
Recent events (1)
  • — Z (S) $11292

1910.36 D01

Serious Gravity 5 4 instances 2 exposed
Issued
Jan 29, 2024
Abate by
Feb 23, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  a) 1204 E. 12th St., Wilmington, DE 19802 (Building #3 East side entry door): On or about August 3, 2023, employees were exposed to delayed egress hazards due to observed turn knob locks attachment on the exit door.   b) 1204 E. 12th St., Wilmington, DE 19802 (Building #3 Front entrance): On or about August 3, 2023, employees were exposed delayed egress hazards due to observed missing door hardware for the exit door.    c) 1204 E. 12th St., Wilmington, DE 19802 (Building #4 East side door): On or about August 3, 2023, employees were exposed delayed egress hazards due to observed turn knob lock attachment on the exit door.   d) 1204 E. 12th St., Wilmington, DE 19802 (Building #4 Rear door): On or about August 3, 2023, employees were exposed delayed egress hazards due to observed hasp attachment and turn knob lock attached to exit door.
Recent events (1)
  • — Z (S) $0

1910.37 A03

Serious Gravity 5 4 instances 2 exposed
Issued
Jan 29, 2024
Abate by
Feb 23, 2024
Penalty
Initial $9,680 · Current $9,680
1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  a) 1204 E. 12th St., Wilmington, DE 19802 (North Side Door/Building #3): On or about August 3, 2023, the rear exit door (North-side) was observed blocked by items such as but not limited to pallets which can weigh up to 1000 lbs. exposing employees to trip hazards and delayed egress in the event of an emergency.  b) 1204 E. 12th St., Wilmington, DE 19802 (South Side Door/Building #3): On or about August 3, 2023, the front exit door (South side) was observed by items such as but not limited to pallets which can weigh up to 1000 lbs. exposing employees to trip hazards and delayed egress in the event of an emergency.  c) 1204 E. 12th St., Wilmington, DE 19802 (East Side Door/Building #3): On or about August 3, 2023, the (East side) exit door was observed blocked by items such as but not limited to pallets which can weigh up to 1000 lbs. exposing employees to trip hazards and delayed egress in the event of an emergency.  d) 1204 E. 12th St., Wilmington, DE 19802 (North Side Door/Building #4): On or about August 3, 2023, the (North side) exit door was observed blocked by items such as but not limited to pallets which can weigh up to 1000 lbs. exposing employees to trip hazards and delayed egress in the event of an emergency.
Recent events (1)
  • — Z (S) $9680

1910.37 A04

Serious Gravity 5 5 instances 2 exposed
Issued
Jan 29, 2024
Abate by
Feb 23, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:   a) 1204 E. 12th St., Wilmington, DE 19802 (Front Exit Door/Building #3): On or about August 3, 2023, employees were exposed to hazards related to emergency evacuation of the building while working in the area where the exit sign leading to the egress access was not illuminated to ensure visibility in the event of an emergency evacuation.  b) 1204 E. 12th St., Wilmington, DE 19802 (Building #3 sprinkler): On or about August 3, 2023, employees were exposed to hazards related to emergency evacuation of the building while working in the area where the sprinkler system was not inspected to ensure serviceability in the event of an emergency evacuation.  c) 1204 E. 12th St., Wilmington, DE 19802 (Building #4 sprinkler): On or about August 3, 2023, employees were exposed to hazards related to emergency evacuation of the building while working in the area where the sprinkler system was not inspected to ensure serviceability in the event of an emergency evacuation.  d) 1204 E. 12th St., Wilmington, DE 19802 (Building #3 emergency lighting): On or about August 3, 2023, employees were exposed to hazards related to emergency evacuation of the building when independent emergency lighting throughout the buildings were observed damaged or nonfunctional resulting in delayed egress due to low light, smoke, or fire conditions during an emergency evacuation.  e) 1204 E. 12th St., Wilmington, DE 19802 (Building #4 emergency lighting): On or about August 3, 2023, employees were exposed to hazards related to emergency evacuation of the building when independent emergency lighting throughout the buildings were observed damaged or nonfunctional resulting in delayed egress due to low light, smoke, or fire conditions during an emergency evacuation.
Recent events (1)
  • — Z (S) $0

1910.37 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 29, 2024
Abate by
Feb 23, 2024
Penalty
Initial $9,680 · Current $9,680
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  a) 1204 E. 12th St., Wilmington, DE 19802 (Building #3 Northside/rear door): On or about August 3, 2023, emergency exits were not visible or marked with an "exit" sign as required.
Recent events (1)
  • — Z (S) $9680

1910.37 B04

Serious Gravity 5 2 instances 4 exposed
Issued
Jan 29, 2024
Abate by
Feb 23, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:  a) 1204 E. 12th St., Wilmington, DE 19802 (Building #3 Throughout): On or about August 3, 2023, the employer failed to provide directional signs along the exit access to provide direction of travel to the nearest exit and exit discharge of an approximately 45,000 ft.� warehouse.  b) 1204 E. 12th St., Wilmington, DE 19802 (Building #4 Throughout): On or about August 3, 2023, the employer failed to provide directional signs along the exit access to provide direction of travel to the nearest exit and exit discharge in the proximate 45,000 ft.�  warehouse.
Recent events (1)
  • — Z (S) $0

1910.157 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 29, 2024
Abate by
Feb 23, 2024
Penalty
Initial $8,067 · Current $8,067
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a) 1204 E. 12th St., Wilmington, DE 19802 (Building #3- Throughout): On or about August 3, 2023, the employer failed to ensure that portable fire extinguishers were properly mounted and visible.
Recent events (1)
  • — Z (S) $8067

1910.157 E02

Serious Gravity 5 2 instances 2 exposed
Issued
Jan 29, 2024
Abate by
Feb 23, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(1): The employer shall be responsible for the inspection, maintenance, and testing of all portable fire extinguishers in the workplace:  a) 1204 E. 12th St., Wilmington, DE 19802 (Building #3- Throughout): On or about August 3, 2023, monthly inspections of the portable fire extinguishers located at the worksite were not conducted as required.  b) 1204 E. 12th St., Wilmington, DE 19802 (Building #4 - Throughout): On or about August 3, 2023, monthly inspections of the portable fire extinguishers located at the worksite were not conducted as required.
Recent events (1)
  • — Z (S) $0

1910.303 B07 I

Serious Gravity 5 7 instances 2 exposed
Issued
Jan 29, 2024
Abate by
Feb 23, 2024
Penalty
Initial $9,680 · Current $9,680
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment.  a) 1204 E. 12th St., Wilmington, DE 19802 (Building #3 Panel # 3): On or about August 3, 2023, and at times prior thereto and thereafter, employees were exposed to hazards when the Western Electric Panel # Z 169510 were observed energized with missing parts and were not effectively closed exposing employees to shock hazards.  b) 1204 E. 12th St., Wilmington, DE 19802 (Building #3 Panel # 4): On or about August 3, 2023, and at times prior thereto and thereafter, employees were exposed to hazards when electrical circuit panel boxes were observed energized with missing parts and were not effectively closed exposing employees to shock hazards.  c) 1204 E. 12th St., Wilmington, DE 19802 (Building #4 General Electric Panel #7): Employees were required to enter an ineffectively guarded General Electric panel number Y-724632 to activate/deactivate overhead lighting daily. The electrical panel observed by CSHO displayed missing screws holes. The opened holes exposed employees to electrical shock hazards on a daily basis.  d) 1204 E. 12th St., Wilmington, DE 19802 (Building #3/Rear Wall Trough): Employees were exposed to electrical wiring that was not effectively closed.   e) 1204 E. 12th St., Wilmington, DE 19802 (Building #3/Rear Overhead Door Control): Employees were exposed to electrical wiring that was not effectively closed.  f) 1204 E. 12th St., Wilmington, DE 19802 (Building #/4/unknown conduit picture number 20230803_174406134): Employees were exposed to electrical wiring that was not effectively closed. Four wires were observed coming from the conduit with wire nuts attached.  g) 1204 E. 12th St., Wilmington, DE 19802 (Building #/4/unknown junction box picture number 20230803_174409474): Employees were exposed to electrical wiring that was not effectively closed. Three wires identified as green, red, black were exposed without a proper cover.  h) 1204 E. 12th St., Wilmington, DE 19802 (Building #/3/unknown Light switch picture number 20230803_163535096): Employees were exposed to electrical wiring that was not effectively closed. CSHO observed a thermostat connected to a electrical switch that was not effectively closed.
Recent events (1)
  • — Z (S) $9680

1910.303 B07 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 29, 2024
Abate by
Feb 23, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(iv): Equipment with damaged parts that may adversely affect its safe operation or its mechanical strength, such as broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating parts shall not be used:  a) 1204 E. 12th St., Wilmington, DE 19802 (Building # 3 Lavatory entrance): On or about August 3, 2023, employees were exposed to hazards when energized electrical equipment were observed with damage resulting in unsafe working and operating conditions.
Recent events (1)
  • — Z (S) $0

1910.303 B08 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 29, 2024
Abate by
Feb 23, 2024
Penalty
Initial $9,680 · Current $9,680
29 CFR  1910.303(b)(8)(i): Electrical equipment was not firmly secured to the surface on which it was mounted.   a) 1204 E. 12th St., Wilmington, DE 19802 (Building #3 Unidentified Column): On or about August 3, 2023, the employer failed to ensure electrical equipment was properly secured to its mounting surface, exposing employees to the hazards of electrical shock. Electrical lines were observed damaged and pulling away from columns unsecured, exposing employees to live wires and caught in hazards.
Recent events (1)
  • — Z (S) $9680

1910.303 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 29, 2024
Abate by
Feb 23, 2024
Penalty
Initial $6,453 · Current $6,453
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) 1204 E. 12th St., Wilmington, DE 19802 (Building #4): On or about August 3, 2023, the access space at the front of the switch disconnects were blocked with loaded pallets exposing employees to potential shock and trip hazards due to limited access to the disconnects in the event of an emergency.
Recent events (1)
  • — Z (S) $6453

1910.303 F02

Serious Gravity 5 2 instances 2 exposed
Issued
Jan 29, 2024
Abate by
Feb 23, 2024
Penalty
Initial $8,067 · Current $8,067
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  a) 1204 E. 12th St., Wilmington, DE 19802 (Building #3 Panel #3): On or about August 3, 2023, and at times prior thereto and thereafter, the employer failed to properly identify all circuit breakers inside the Western Electric Panel # Z 169510 located on the east wall. CSHO observed the panel labeling did not clearly specify the purpose of all circuit breakers within the panel.  b) 1204 E. 12th St., Wilmington, DE 19802 (Building #3 Panel #4): On or about August 3, 2023, and at times prior thereto and thereafter, the employer failed to properly identify all circuit breakers inside the Western House Electric Corporation breaker panel located on the west wall. CSHO observed the panel did not have any labeling to clearly specify the purpose of all circuit breakers within the panel.
Recent events (1)
  • — Z (S) $8067

1910.304 F01 VIII

Serious Gravity 10 2 instances 2 exposed
Issued
Jan 29, 2024
Abate by
Feb 23, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.304(f)(1)(viii):29 CFR 1910.304(f)(1)(viii): Circuit breakers used as switches in 120-volt and 277-volt, fluorescent lighting circuits were not listed and marked "SWD."  a) 1204 E. 12th St., Wilmington, DE 19802 (Building #3 Panel #3): On or about August 3, 2023, and at times prior thereto and thereafter, employees were exposed to potential arc flash and electrical shock while using non "SWD" circuit breaker to activate and deactivate overhead fluorescent lights that operated in 120V and 277 Volt systems.    b) 1204 E. 12th St., Wilmington, DE 19802 (Building #3 Panel #4): On or about August 3, 2023, and at times prior thereto and thereafter, employees were exposed to potential arc flash and electrical shock while using NON "SWD" circuit breaker to activate and deactivate overhead fluorescent lights that operated in 120V and 277 Volt systems.
Recent events (1)
  • — Z (S) $0

1910.305 A02 X

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 29, 2024
Abate by
Feb 23, 2024
Penalty
Initial $6,453 · Current $6,453
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.  a) 1204 E. 12th St., Wilmington, DE 19802 (Building #4): On or about August 3, 2023, employees were exposed to electrical shock hazards when an extension cord (orange flexible cord) used to service a 120 V portable air conditioner was draped across a bathroom doorway and run beneath the door molding where nails and other protrusions could potentially scrape the outer jacket damaging the flexible cord.
Recent events (1)
  • — Z (S) $6453

View DEE Packaging Solutions, INC.'s full OSHA safety record →