Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DGX

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DGX in 210 S 16TH STREET SUITE 115, OMAHA, NE 68102 (NAICS 452319). OSHA activity number 346881865.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch DGX — free Get an email when a new federal OSHA severe-injury report for DGX is published. One employer, no account, unsubscribe in one click.
Establishment
DGX
Site address
210 S 16TH STREET SUITE 115
City
OMAHA
State
NE
ZIP
68102
Mailing
210 S 16TH STREET SUITE 115, OMAHA, NE 68102
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
452319
Employees
6
Ownership type
A

2 citations on file for this inspection.

1910.334 A02 I

Other-than-serious Gravity 5 1 instance 6 exposed
Issued
Oct 13, 2023
Abate by
Nov 8, 2023
Penalty
Initial $8,929 · Current $6,250 Reduced
29 CFR  1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  The employer was failing to ensure employees were protected from electrical shock and burn hazards. An extension cord used to provide power to a freezer unit was unable to be inspected for signs of external defects and signs of internal damage. This was most recently observed at 210 S 16th Street, Suite 115, Omaha, Nebraska on August 3, 2023.
Recent events (2)
  • — I (O) $6250.3
  • — Z (S) $8929

1910.305 G01 IV

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Oct 13, 2023
Abate by
Nov 8, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv):Extension cords and/or power strips were being used in lieu of permanent building wiring.  The employer was failing to ensure that all employees are not exposed to electrical shock and burn hazards. This was most recently documented on August 3, 2023 at 210 S 16th Street, Suite 115, Omaha, Nebraska. The employer failed to ensure that extension cords were not used in lieu of permanent wiring. A freezer unit was plugged into an outlet, using an extension cord.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View DGX's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346881865.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.