FORT LAUDERDALE, FL —
OSHA Inspection: G&R MINERAL SERVICES, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of G&R MINERAL SERVICES, INC. in 2600 EISENHOWER BLVD., FORT LAUDERDALE, FL 33316 (NAICS 811310). OSHA activity number 346888159.
Where did this inspection happen?
- Establishment
- G&R MINERAL SERVICES, INC.
- Site address
- 2600 EISENHOWER BLVD.
- City
- FORT LAUDERDALE
- State
- FL
- ZIP
- 33316
- Mailing
- 2355 ALTON ROAD, BIRMINGHAM, AL 35210
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811310
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $11292.00 · Current $10000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: (a) On or about August 4, 2023, and at times prior to, at 2600 Eisenhower Blvd., Fort Lauderdale, FL 33316, South Cross Screw area, employees were exposed to amputation and electrical hazards, in that the employer did not ensure that the lockout/tagout procedure(s) for the south screw described the scope, the type and magnitude of the participating hazardous energies, the location and identity of the disconnecting means, and the specific steps for shutting down and controlling hazardous energy, the placement and removal of lockout/tagout devices, and the testing of equipment during assembly and adjustment.
Recent events (3)
- — F (S) $10000
- — C (S) $11292
- — Z (S) $11292
1910.147 F01 II
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $14035.00 Reduced
General-duty citation text
29 CFR 1910.147(f)(1)(ii): When lockout or tagout devices were temporarily removed from the energy isolating device and the machine or equipment was energized to test or position the machine, equipment, or component thereof, the employees were not removed from the machine or equipment area in accordance with paragraph (e)(2) of this section: a) On or about August 4, 2023, at 2600 Eisenhower Blvd., Fort Lauderdale, FL 33316, South Cross Screw area, employees were exposed to caught-in and amputation hazards, in that the employer did not ensure employees were removed from the unguarded screw area at the time locks were removed and the screw was re-energized and rotated.
Recent events (3)
- — F (O) $14035
- — C (S) $16131
- — Z (S) $16131
1910.147 F02 I
- Issued
- Abate by
- Penalty
- Initial $11292.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(f)(2)(i): When outside servicing personnel were engaged in activities in a facility, the onsite employer and the outside employer did not inform each other of their respective lockout or tagout procedures: a) On or about August 4, 2023, at 2600 Eisenhower Blvd., Fort Lauderdale, FL 33316, South Cross Screw area, employees were exposed to caught-in and amputation hazards, in that the onsite employer and the outside employer did not review and coordinate in advance the lockout or tagout procedures and the methods for lock removal, power reconnection, and controlled rotation of the unguarded screw.
Recent events (3)
- — F (S) $0
- — C (S) $11292
- — Z (S) $11292
More inspections at G&R MINERAL SERVICES, INC.
MIAMI, FL—2000-05-31 00:00:00
G & R MINERAL SERVICES, INC.
View G&R MINERAL SERVICES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 811310)
PATERSON, NJ—2026-07-09 00:00:00
YHONNY REFRIGERATION
CHRISTIANSBURG, VA—2026-07-09 00:00:00
BGIS GLOBAL INTEGRATED SOLUTION US, LLC
SEATTLE, WA—2026-07-09 00:00:00
WA317992010 - FLAGSHIP MANAGEMENT LLC
STATESBORO, GA—2026-07-08 00:00:00
TAYLOR BUILT PRODUCTS
ANCHORAGE, AK—2026-07-08 00:00:00
ANGUS ENTERPRISES
More inspections in FL
DELAND, FL—2026-07-16 00:00:00
BALL FABRICS
GAINESVILLE, FL—2026-07-16 00:00:00
WACKY SAUCES LLC
FORT WALTON BEACH, FL—2026-07-16 00:00:00
WASTE MANAGEMENT, INC. OF FLORIDA
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
PALM COAST, FL—2026-07-16 00:00:00
J & J TREE EXPERTS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346888159.