INDIANA, PA —
OSHA Inspection: SPECIALTY TIRES OF AMERICA, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SPECIALTY TIRES OF AMERICA, INC. in 1600 WASHINGTON STREET, INDIANA, PA 15701 (NAICS 326211). OSHA activity number 346888670.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SPECIALTY TIRES OF AMERICA, INC.
- Site address
- 1600 WASHINGTON STREET
- City
- INDIANA
- State
- PA
- ZIP
- 15701
- Mailing
- 1600 WASHINGTON STREET, INDIANA, PA 15701
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326211
- Employees
- 125
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.333 A01
- Issued
- Dec 19, 2023
- Penalty
- Initial $14,063 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.333(a)(1): "Deenergized parts." Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no increased exposure to electrical burns or to explosion due to electric arcs. (A)Job site 1600 Washington Street, Indiana, PA 15701: on or about August 4, 2023 employees were exposed to electrical shock hazards ,440V exposed conductors, while attempting to reset a nitrogen timer inside the control panel of the number 63 press.
Recent events (2)
- — I (O) $7000
- — Z (S) $14063
1910.138 A
- Issued
- Dec 19, 2023
- Abate by
- Jan 17, 2024
- Penalty
- Initial $0 · Current $7,000
General-duty citation text
29 CFR 1910.138(a):The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes. (A)Job site 1600 Washington Street, Indiana, PA 15701: on or about August 4, 2023 employees were exposed to electrical shock hazards ,440V exposed conductors, while attempting to reset a nitrogen timer inside the control panel of the number 63 press.
Recent events (2)
- — I (O) $7000
- — Z (S) $0
More inspections at Specialty Tires of America, INC.
View Specialty Tires of America, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326211)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346888670.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.