BLYTHEVILLE, AR —
OSHA Inspection: NIBCO INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of NIBCO INC. in 301 S PROMISE LAND ROAD, BLYTHEVILLE, AR 72315 (NAICS 331511). OSHA activity number 346891815.
Where did this inspection happen?
- Establishment
- NIBCO INC.
- Site address
- 301 S PROMISE LAND ROAD
- City
- BLYTHEVILLE
- State
- AR
- ZIP
- 72315
- Mailing
- 301 S PROMISE LAND ROAD, BLYTHEVILLE, AR 72315
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331511
- Employees
- 230
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $16131.00
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about August 8, 2023, at the BMM Molding Machine, employees performed maintenance activities including, but not limited to repairing the "bend gates " on machinery and equipment such as, but not limited as the 10861 BMM Molding Machine without using machine specific energy control procedures.
Recent events (3)
- — F (S) $16131
- — C (S) $16131
- — Z (S) $16131
1910.147 C04 II B
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. On or about August 8, 2023, at the BMM Molding Machine, employees performed servicing and maintenance activities including, but not limited to repairs and lubrication. The machine specific procedures did not include specific procedural steps to control stored energy such as, but not limited to air and the draw.
Recent events (3)
- — F (S) $0
- — C (S) $16131
- — Z (S) $16131
More inspections at NIBCO INC.
NACOGDOCHES, TX—2025-07-03 00:00:00
NIBCO, INC.
BLYTHEVILLE, AR—2025-03-10 00:00:00
NIBCO INC.
NACOGDOCHES, TX—2022-12-06 00:00:00
NIBCO, INC.
GREENSBORO, GA—2019-02-26 00:00:00
NIBCO INC.
GREENSBORO, GA—2016-03-10 00:00:00
NIBCO INC.
View NIBCO INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331511)
CORSICANA, TX—2026-07-01 00:00:00
OIL CITY IRON WORKS, INC.
CORNWALL, PA—2026-07-01 00:00:00
PRL INDUSTRIES INC
CORNWALL, PA—2026-07-01 00:00:00
PRL INDUSTRIES INC
EASTON, PA—2026-07-01 00:00:00
VICTAULIC COMPANY
HAMBURG, PA—2026-06-18 00:00:00
HAMBURG PLOW WORKS, INC.
More inspections in AR
SILOAM SPRINGS, AR—2026-07-15 00:00:00
CR CRAWFORD CONSTRUCTION LLC
VAN BUREN, AR—2026-07-14 00:00:00
MILLAR PARTNERS, LLC
BRINKLEY, AR—2026-07-14 00:00:00
ROGER WILKISON FARMS PARTNERSHIP
SEARCY, AR—2026-07-14 00:00:00
MASTER?S PLASTERING & MORE INC
LITTLE ROCK, AR—2026-07-09 00:00:00
NABHOLZ CONSTRUCTION CORPORATION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346891815.