MINEOLA, NY —
OSHA Inspection: MIKE THE GLAZIER 2 LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MIKE THE GLAZIER 2 LLC in 133 EAST JERICHO TURNPIKE, MINEOLA, NY 11501 (NAICS 238150). OSHA activity number 346893969.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MIKE THE GLAZIER 2 LLC
- Site address
- 133 EAST JERICHO TURNPIKE
- City
- MINEOLA
- State
- NY
- ZIP
- 11501
- Mailing
- 133 EAST JERICHO TURNPIKE, MINEOLA, NY 11501
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238150
- Employees
- 1
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.157 C01
- Issued
- Nov 1, 2023
- Penalty
- Initial $2,009 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Worksite: 133 East Jericho Turnpike, Mineola, NY 11779 - Fire extinguishers were not mounted and were blocked by materials; on or about 8/8/23. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
- — I (S) $1000
- — Z (S) $2009
1910.303 B02
- Issued
- Nov 1, 2023
- Penalty
- Initial $2,679 · Current $3,500
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Worksite: 133 East Jericho Turnpike, Mineola, NY 11779 - An electrical junction box was not mounted and hanging from the ceiling; on or about 8/8/23. b) Worksite: 133 East Jericho Turnpike, Mineola, NY 11779 - An electrical box with a switch was not mounted and hanging from the ceiling; on or about 8/8/23. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
- — I (S) $3500
- — Z (S) $2679
1910.305 B02 I
- Issued
- Nov 1, 2023
- Penalty
- Initial $2,679 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) Worksite: 133 East Jericho Turnpike, Mineola, NY 11779 - A junction box used to power the emergency backup light was missing a cover; on or about 8/8/23. b) Worksite: 133 East Jericho Turnpike, Mineola, NY 11779 - An outlet box used to power the alarm system was missing a cover; on or about 8/8/23. c) Worksite: 133 East Jericho Turnpike, Mineola, NY 11779 - A light switch used in the warehouse was missing a cover; on or about 8/8/23. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $2679
1910.305 G02 II
- Issued
- Nov 1, 2023
- Penalty
- Initial $2,679 · Current $3,500
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:(a)(LOCATION)(IDENTIFY EQUIPMENT AND CONDITION(S))(STATE HAZARD(S) TO EMPLOYEE(S)) a) Worksite: 133 East Jericho Turnpike, Mineola, NY 11501 - Employee(s) were using a worn electric cord repaired with duct tape to power a fan in the warehouse exposing them to electrical hazards; on or about 8/8/23. b) Worksite: 133 East Jericho Turnpike, Mineola, NY 11501 - Employee(s) were using a worn electric cord repaired with yellow tape to power a light in the warehouse exposing them to electrical hazards; on or about 8/8/23. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
- — I (S) $3500
- — Z (S) $2679
1910.305 G02 III
- Issued
- Nov 1, 2023
- Penalty
- Initial $2,679 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) Worksite: 133 East Jericho Turnpike, Mineola, NY 11501 - Employee(s) were using an electric cord with worn strain relief to power an outlet in the warehouse exposing them to electrical hazards; on or about 8/8/23. b) Worksite: 133 East Jericho Turnpike, Mineola, NY 11501 - Employee(s) were using an electric cord with worn strain relief to power a hot melt machine in the warehouse exposing them to electrical hazards; on or about 8/8/23. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $2679
1910.37 A03
- Issued
- Nov 1, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) Worksite: 133 East Jericho Turnpike, NY 11501 - The main exit door in the warehouse was blocked with various items/material/equipment and the employer did not maintain exit access; on or about 8/8/23. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.37 B02
- Issued
- Nov 1, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) Worksite: 133 East Jericho Turnpike, Mineola, NY 11779 - The rear emergency exit did not have an exit sign; on or about 8/8/23. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238150)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346893969.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.