Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERICAN-3 FAB INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AMERICAN-3 FAB INC in 2221 INNOVATION DRIVE, DE PERE, WI 54115 (NAICS 332999). OSHA activity number 346900467.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American-3 FAB INC — free Get an email when a new federal OSHA severe-injury report for American-3 FAB INC is published. One employer, no account, unsubscribe in one click.
Establishment
AMERICAN-3 FAB INC
Site address
2221 INNOVATION DRIVE
City
DE PERE
State
WI
ZIP
54115
Mailing
2221 INNOVATION DRIVE, DE PERE, WI 54115
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
85
Ownership type
A

5 citations on file for this inspection.

1910.106 E09 III

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 30, 2023
Abate by
Nov 29, 2023
Penalty
Initial $7,813 · Current $5,469 Reduced
29 CFR  1910.106(e)(9)(iii): "Waste and residue." Combustible waste material and residues in a building or unit operating area shall be kept to a minimum, stored in covered metal receptacles and disposed of daily.  On or about August 3, 2023, with regard to an establishment located at 2221 Innovation Drive, De Pere, WI 54115, the employer did not ensure that combustible waste products such as, but not limited to, cleaning rags with lacquer or degreaser on them were disposed of in covered metal containers and disposed of daily.
Recent events (2)
  • — I (S) $5469.1
  • — Z (S) $7813

1910.252 A02 VII

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 30, 2023
Abate by
Jan 16, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.252(a)(2)(vii): Relocation of combustibles. Where practicable, all combustibles shall be relocated at least 35 feet (10.7 m) from the work site. Where relocation is impracticable, combustibles shall be protected with flameproofed covers or otherwise shielded with metal or asbestos guards or curtains.  On or about August 3, 2023, with regard to an establishment located at 2221 Innovation Drive, De Pere, WI 54115, the employer did not ensure that employees using combustible material, such as Sherwin William Lacquer Thinner K22, had located that material at least 35 feet from the worksite or protected the material with flameproof covers or adequate shielding.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 E06 II

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 30, 2023
Abate by
Jan 16, 2024
Penalty
Initial $7,813 · Current $5,469 Reduced
29 CFR  1910.106(e)(6)(ii): Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 �F (37.8 �C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.  On or about August 3, 2023, with regard to an establishment located at 2221 Innovation Drive, De Pere, WI 54115, employees dispensing Sherwin William Lacquer Thinner K22 into secondary metal containers did not ensure that the containers were bonded prior to conducting the filling operation.
Recent events (2)
  • — I (S) $5469.1
  • — Z (S) $7813

1910.252 C11 I

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 30, 2023
Abate by
Nov 29, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.252(c)(11)(i): Manufacturer's instructions. In the use of cleaning materials, because of their possible toxicity or flammability, appropriate precautions such as manufacturers instructions shall be followed.  On or about August 3, 2023, with regard to an establishment located at 2221 Innovation Drive, De Pere, WI 54115, the employer did not ensure that employees using chemicals such as, but not limited to, Sherwin Williams Lacquer Thinner K22 and Sprayway Black Label D3 Citrus Degreaser were using appropriate precautions against flammability hazards as identified in the manufacturers instructions.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 30, 2023
Abate by
Nov 29, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(h)(3)(ii): Employee training shall include at least the physical, health, simple asphyxiation, combustible dust, and pyrophoric gas hazards, as well as hazards not otherwise classified, of the chemicals in the work area.  On or about August 3, 2023, with regard to an establishment located at 2221 Innovation Drive, De Pere, WI 54115, the employer did not ensure that employees had received training on the pyrophoric gas hazards of the chemicals they were using in the workplace.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346900467.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.