PASADENA, TX —
OSHA Inspection: HARPER BROTHERS CONSTRUCTION, LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of HARPER BROTHERS CONSTRUCTION, LLC in 12703 PORT ROAD, PASADENA, TX 77507 (NAICS 237990). OSHA activity number 346900780.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HARPER BROTHERS CONSTRUCTION, LLC
- Site address
- 12703 PORT ROAD
- City
- PASADENA
- State
- TX
- ZIP
- 77507
- Mailing
- 654 NORTH SAM HOUSTON PKWY E. SUITE 330, HOUSTON, TX 77060
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237990
- Employees
- 300
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.600 A06 I
- Issued
- Feb 5, 2024
- Abate by
- Mar 1, 2024
- Penalty
- Initial $16,131 · Current $16,131
General-duty citation text
29 CFR 1926.600(a)(6)(i): For lines rated 50kV or below, a minimum of 10 feet was not maintained between the energized line and the equipment: a) On or about August 9, 2023, an excavator was operated within 10 feet of overhead power lines carrying approximately 12.2kV of electricity, exposing employees to electrocution hazards.
Recent events (2)
- — I (O) $16131
- — Z (S) $16131
1926.959 D03 II
- Issued
- Feb 5, 2024
- Abate by
- Mar 1, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.959(d)(3)(ii): The mechanical equipment was not positioned so that its uninsulated portions could not approach the energized lines or equipment any closer than the minimum approach distances established by the employer: a) On or about August 9, 2023, an excavator was positioned where the uninsulated boom could approach an energized overhead power line closer than the minimum approach distance, exposing employees to electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.950 D01
- Issued
- Feb 5, 2024
- Abate by
- Mar 1, 2024
- Penalty
- Initial $16,131 · Current $16,131
General-duty citation text
29 CFR 1926.950(d)(1): The nominal voltages of lines and equipment was not determined before work on or near the lines or equipment was started: a) On or about August 9, 2023, the nominal voltages of overhead powerlines was not determined prior to operating an excavator beneath the lines, exposing employees to electrical hazards.
Recent events (2)
- — I (O) $16131
- — Z (S) $16131
More inspections at Harper Brothers Construction, LLC
View Harper Brothers Construction, LLC's full OSHA safety record →
More inspections in this industry (NAICS 237990)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346900780.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.