Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LATHAM STAIRS & MILLWORKS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LATHAM STAIRS & MILLWORKS, INC. in 1850 N STEMMONS STREET, SANGER, TX 76266 (NAICS 337110). OSHA activity number 346907090.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Latham Stairs & Millworks, INC. — free Get an email when a new federal OSHA severe-injury report for Latham Stairs & Millworks, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1850 N STEMMONS STREET
City
SANGER
State
TX
ZIP
76266
Mailing
1850 N STEMMONS STREET, SANGER, TX 76266
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
32
Ownership type
A

9 citations on file for this inspection.

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 18, 2023
Abate by
Sep 18, 2023
Penalty
Initial $4,687 · Current $2,812 Reduced
29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace:   On August 14, 2023, and times prior thereto, employee(s) wearing full face and half face 3M respirators were not medically cleared and exposed to paint fumes while performing painting activities.
Recent events (2)
  • — I (S) $2812.2
  • — Z (S) $4687

1910.134 F02

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 18, 2023
Penalty
Initial $5,313 · Current $3,188 Reduced
29 CFR  1910.134(f)(2):Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator.  On August 14, 2023, and times prior thereto, employees wearing tight-fitting  3M full face and North half mask respirators to perform painting activities were not fit tested to use respirators and exposed the employees to respiratory inhalation hazards.
Recent events (2)
  • — I (S) $3187.8
  • — Z (S) $5313

1910.134 G01 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 18, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function.   On August 14, 2023, and times prior thereto, the employer permitted employees with facial hair to wear respirators that could not be properly tight-fitted exposing employees to a respiratory inhalation hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L04 III

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 18, 2023
Abate by
Sep 18, 2023
Penalty
Initial $6,250 · Current $3,750 Reduced
29 CFR  1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years   On August 14, 2023, and times prior thereto, powered industrial truck operators were not re-evaluated as required every three years exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $3750
  • — Z (S) $6250

1910.178 L06

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 18, 2023
Abate by
Sep 18, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):   On August 14, 2023, and times prior thereto, operators of the Komatsu forklifts were not trained and certified to operate the equipment prior to use exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 Q07

Other-than-serious 1 instance 4 exposed
Issued
Aug 18, 2023
Abate by
Sep 18, 2023
Penalty
Initial $746 · Current $448 Reduced
29 CFR  1910.178(q)(7): Powered industrial truck(s) which were used on a round-the-clock basis were not examined for defects after each shift.   On August 14, 2023, and times prior thereto, the employer did not ensure daily inspections on the industrial trucks were conducted, exposing employees to struck-by hazards.
Recent events (2)
  • — I (O) $447.6
  • — Z (O) $746

1910.305 G01 IV A

Other-than-serious 1 instance 6 exposed
Issued
Aug 18, 2023
Penalty
Initial $746 · Current $448 Reduced
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.   On August 14, 2023, and times prior thereto, an extension cord wrapped around a metal rack was used in lieu of permanent wiring to energize two floor fans exposing employees to electrical shock hazards.
Recent events (2)
  • — I (O) $447.6
  • — Z (O) $746

1910.305 G02 III

Other-than-serious 2 instances 6 exposed
Issued
Aug 18, 2023
Penalty
Initial $746 · Current $448 Reduced
29 CFR  1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws.   On August 14, 2023, and times prior thereto, employees used floor fans and power cords with the outer sheathing pulled away from the terminal screws and exposing internal wiring.  The employees were exposed to electrical shock hazards.  a)  Max Air Pro fan power cord pulled away from the terminal exposing internal wiring,  b)  Big Air floor fan power cord pulled away from the terminal exposing internal wiring.
Recent events (2)
  • — I (O) $447.6
  • — Z (O) $746

1910.305 B01

Other-than-serious 1 instance 6 exposed
Issued
Aug 18, 2023
Penalty
Initial $877 · Current $526 Reduced
29 CFR  1910.305(b)(1): Holes in electrical equipment (boxes, Panels, etc) were not effectively closed (missing breakers, etc.)   On August 14, 2023, and times prior thereto, a knockout was missing from energized electrical panel boxes exposing employees to electrical shock hazards.
Recent events (2)
  • — I (O) $526.2
  • — Z (O) $877

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346907090.