Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. POSTAL SERVICE - CATA?O DMDU ANNEX

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of U.S. POSTAL SERVICE - CATA?O DMDU ANNEX in 100 AVE LOS CONQUISTADORES, CATANO, PR 00962 (NAICS 491110). OSHA activity number 346909203.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Postal Service - Cata?O Dmdu Annex — free Get an email when a new federal OSHA severe-injury report for U.S. Postal Service - Cata?O Dmdu Annex is published. One employer, no account, unsubscribe in one click.
Site address
100 AVE LOS CONQUISTADORES
City
CATANO
State
PR
ZIP
00962
Mailing
100 AVE LOS CONQUISTADORES, CATANO, PR 00962
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
491110
Employees
55
Ownership type
A

8 citations on file for this inspection.

1910.158 C01

Other-than-serious Gravity 5 1 instance 55 exposed
Issued
Jan 17, 2024
Abate by
Mar 25, 2024
Penalty
Initial $9,218 · Current $4,609 Reduced
29 CFR  1910.158(c)(1):  Reels and cabinets. Where reels or cabinets are provided to contain fire hose, the employer shall assure that they are designed to facilitate prompt use of the hose valves, the hose, and other equipment at the time of a fire or other emergency. The employer shall assure that the reels and cabinets are conspicuously identified and used only for fire equipment.  a) On or about August 16, 2023, at the US Postal Service, Cata�o DMDU Annex - Entrance to the Automated Parcel and Bundle Sorter (APBS) wheeled carts were obstructing a fire hose cabinet.  NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — I (O) $4609
  • — Z (S) $9218

1910.178 Q07

Other-than-serious Gravity 10 1 instance 55 exposed
Issued
Jan 17, 2024
Abate by
Mar 25, 2024
Penalty
Initial $16,131 · Current $8,066 Reduced
29 CFR  1910.178(q)(7):  Powered industrial truck(s) which were used on a round-the-clock basis were not examined for defects after each shift:   a) On or about August 15, 2023, at the U.S. Postal Service, Cata�o DMDU Annex - a Toyota Electric Forklift Truck, Model 7FBCU25, Serial #64734, was in operation with broken horn and beacon lights, exposing employees (pedestrians and other forklift operators) to struck-by hazards during operations.    NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — I (O) $8065.5
  • — Z (S) $16131

1910.212 A01

Serious Gravity 5 1 instance 55 exposed
Issued
Jan 17, 2024
Abate by
Mar 25, 2024
Penalty
Initial $13,828 · Current $6,914 Reduced
29 CFR  1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   a) On or about August 15, 2023, at the US Postal Service Cata�o DMDU Annex - the Low-Cost Universal Sorter (LCUS) #3 conveyor, was found with protruding rods on all rollers. The Low-Cost Universal Sorter (LCUS) relay switch that controls the conveyor rollers was not operational, allowing the rollers to continue operating when the machines complete the task, exposing employees to caught-by hazard.           NOTE: Certification and documentation of abatement must be submitted for all the instances of this citation as required by CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — I (S) $6914
  • — Z (S) $13828

1910.303 G01

Other-than-serious Gravity 1 1 instance 55 exposed
Issued
Jan 17, 2024
Abate by
Mar 25, 2024
Penalty
Initial $6,913 · Current $3,457 Reduced
29 CFR  1910.303(g)(1):  Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) On or about August 16, 2023, U.S. Postal Service - Catano DMDU - at the Maintenance Storage Room, an electrical service panel (1DP-6, 1PP-10) was not provided and maintained with a minimum of 3 feet working clearance, exposing employees to electrical hazards.   NOTE:  Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c).
Recent events (2)
  • — I (O) $3456.5
  • — Z (S) $6913

1910.303 G02 I

Serious Gravity 5 1 instance 55 exposed
Issued
Jan 17, 2024
Abate by
Mar 25, 2024
Penalty
Initial $13,828 · Current $6,914 Reduced
29 CFR  1910.303(g)(2)(i):  Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  a) On or about August 16, 2023, the US Postal Service, Cata�o DMDU Annex - Lobby, an electrical junction box did not have a water-tight cover behind the sink, exposing employees to an electrical hazard.   NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — I (S) $6914
  • — Z (S) $13828

1910.37 A04

Other-than-serious 1 instance 55 exposed
Issued
Jan 17, 2024
Abate by
Jan 31, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.37(a)(4):  Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:  a) On or about August 16, 2023, at the US Postal Service, Cata�o DMDU Annex - Battery Room 9, an emergency EXIT light, Brand unknown, was inoperative and with faded lettering.    NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.132 A

Deleted Other-than-serious 1 instance 6 exposed
Issued
Jan 17, 2024
Abate by
Jan 31, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.132(a):  Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers was not provided, used, and/or maintained.   a) On or about August 16, 2023, at the US Postal Service, Cata�o DMDU Annex - Battery Room 9, the following items from the personal protective equipment board were missing: Cap-Off tool, hydrometer and gloves.  In addition, the apron had the side straps missing.  This condition can expose employees to eye and skin injuries through the exposure to corrosive chemicals from the batteries.  NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.141 B01 III

Other-than-serious 1 instance 55 exposed
Issued
Jan 17, 2024
Abate by
Mar 25, 2024
Penalty
Initial $1,294 · Current $647 Reduced
29 CFR 1910.141(b)(1)(iii):  Portable drinking water dispensers were not designed, constructed, and serviced so that sanitary conditions are maintained.  a) On or about August 15, 2023, at the US Postal Service, Cata�o DMDU Annex - water fountains, brand Feel Well Alpine, were found very unkempt, including surrounding area. This condition can expose employees to bacteriological hazards.        NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — I (O) $647
  • — Z (O) $1294

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346909203.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.