Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RON PERRIN WATER TECHNOLOGIES INCORPORATED

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RON PERRIN WATER TECHNOLOGIES INCORPORATED in 2200 HIGGINS LN, HALTOM CITY, TX 76111 (NAICS 561990). OSHA activity number 346915234.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RON Perrin Water Technologies Incorporated — free Get an email when a new federal OSHA severe-injury report for RON Perrin Water Technologies Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
2200 HIGGINS LN
City
HALTOM CITY
State
TX
ZIP
76111
Mailing
301 MARTHA JEAN ST, FORT WORTH, TX 76108
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561990
Employees
10
Ownership type
A

5 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 17, 2023
Abate by
Dec 18, 2023
Penalty
Initial $3,349 · Current $2,009 Reduced
29 CFR 1910.28(b)(1)(i):  Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i):  On or about August 16, 2023, and at times prior thereto, employee(s) working on top of water tower tanks were not provided fall protection at unprotected sides and edges and exposed to a fall hazard of approximately 35-feet to the ground below.
Recent events (2)
  • — I (S) $2009.4
  • — Z (S) $3349

1910.29 B03

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 17, 2023
Abate by
Dec 18, 2023
Penalty
Initial $4,688 · Current $2,813 Reduced
29 CFR 1910.29(b)(3): The employer did not ensure that guardrail systems are capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied in a downward or outward direction within 2 inches (5 cm) of the top edge, at any point along the top rail.   On or about August 16, 2023, and at times prior thereto, the employer allowed employees to use a pulley system on guardrail systems, to haul up equipment onto and off water tank towers and did not ensure the capable of withstanding 200 lbs. exposing employees to fall hazards approximately 35-feet.
Recent events (2)
  • — I (S) $2812.8
  • — Z (S) $4688

1910.140 C13 I

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 17, 2023
Abate by
Dec 18, 2023
Penalty
Initial $4,688 · Current $2,813 Reduced
29 CFR  1910.140(c)(13)(i): Anchorages were not capable of supporting at least 5000 pounds (22.2 kN) for each employee attached.     On or about August 16, 2023, and at times prior thereto, the employer did not ensure anchor points used by employees were capable of withstanding and supporting at least 5000 pounds exposing allowed employees exposing employees to fall hazards approximately 35-feet.
Recent events (2)
  • — I (S) $2812.8
  • — Z (S) $4688

1910.140 C13 II

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 17, 2023
Abate by
Dec 18, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.140(c)(13)(ii): Anchorages were not designed, installed, and used, under the supervision of qualified person, as part of a complete personal fall protection system that maintains a safety factor of at least two:      On or about August 16, 2023, and at times prior thereto, the employer did not ensure anchor points used by employees were designed, installed and used under a competent person which was capable of withstanding and supporting at least 5000 pounds exposing employees to fall hazards approximately 35-feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.30 A03 IV

Other-than-serious 1 instance 3 exposed
Issued
Nov 17, 2023
Abate by
Dec 11, 2023
Penalty
Initial $376 · Current $226 Reduced
29 CFR 1910.30(a)(3)(iv): The employer did not train each employee in the correct use of personal fall protection systems and equipment specified in paragraph (a)(1) of this section, including, but not limited to, proper hook-up, anchoring, and tie-off techniques, and methods of equipment inspection and storage, as specified by the manufacturer.  On or about August 16, 2023, and at times prior thereto, employees were provided training and recognition on proper hook-up, anchoring and tie off techniques of fall protection systems while working on water tanks above 4-feet.
Recent events (2)
  • — I (O) $225.6
  • — Z (O) $376

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346915234.